Wiring Methods - Mitsubishi Electric MELSEC iQ-F FX5 User Manual

Hide thumbs Also See for MELSEC iQ-F FX5:
Table of Contents

Advertisement

Terminal layout of CC-Link connection terminal block
Shows terminal layout of the CC-Link connection terminal block.
(1)
DG
SLD
(1) Terminal block mounting screw
Terminal name
DA
DB
DG
SLD
• To remove the terminal block, loosen terminal block mounting screws on the left and right sides uniformly
and remove the terminal block.
• To install the terminal block, place the terminal block at its predetermined position and tighten the terminal
block mounting screws on the left and right sides uniformly.

Wiring methods

Wiring to a terminal block
Describes wiring to the terminal block.
Connect a Ver.1.10-compatible CC-Link dedicated cable as shown below.
(1)(2)(3)
(1) Blue
(2) Yellow
(3) White
(4) Terminating resistor
• Connect the supplied "terminal resistors" in product at both ends of the CC-Link system. Connect the
terminal resistors between [DA] and [DB].
• Connect the shield wires of a Ver.1.10-compatible CC-Link dedicated cable to the SLD terminal in each
module through the FG terminal. Then ground the cables at both ends with a class D grounding (grounding
resistance: 100  or less). The SLD and FG terminals are connected inside.
• For the terminal processing of when connecting the Ver.1.10-compatible CC-Link dedicated cable to the
terminal block, do not unfasten the DA/DB/DG cable (three wires in one cable) or remove the sheath more
than necessary. (For cables with fillers, cut them using a tool.)
6 WIRING
54
6.2 CC-Link Network Wiring
DA
DB
(1)
Description
Sending or receiving data
Data ground
Shield
(4)