218
A
B: U
PPENDIX
PGRADING
Preliminary Steps
VCX S
S
F
ERVER
OFTWARE
ROM
Prior to performing any upgrade, you should check the following:
Check the configuration type of the system you are going to upgrade.
■
The upgrade procedure you need to perform depends on your VCX
system configuration (see
Hardware
Configurations). You can use the
command to verify the configuration type. Your configuration
determines the correct tar file (or files) required for the upgrade.
You must stop database replication before starting the upgrade
■
process. On replicated systems, check replication status to make sure it
is normal. To check replication status, execute the following steps on
the server hosting the Authentication and Directory services database:
Log in using the cworks account.
Enter:
cd /opt/3com/VCX/vcxdata/bin
Enter:
./checkReplication
The returned status should be NORMAL. If replication errors need to
be cleared:
Enter:
./deleteReplicationErrors
CAUTION: Do not attempt an upgrade if there are replication errors that
cannot be deleted.
Depending on your configuration, you may need to upgrade the
following VCX software components and configurations:
IP Telephony and IP Messaging server software
■
Supported on:
Single-site systems with two servers
■
Multi-site systems that include servers at regional offices, but no
■
branch offices
Multi-site systems that include servers at regional offices and
■
servers at branch offices that use local IP Messaging
IP Telephony server software
■
Supported on:
Single-site systems with four servers
■
Multi-site systems that include servers at regional offices and
■
servers at branch offices that use global IP Messaging
IP Messaging server software
■
V7.1.
V7.1.
X TO
Y
VCX Software Components
and
VCX
vcx-showconfigtype