3Com VCX V7000 Maintenance Manual page 194

Ip telephony solution
Hide thumbs Also See for VCX V7000:
Table of Contents

Advertisement

194
A
A: U
PPENDIX
PGRADING
------------------- Installation Completed Successfully -------------------
------------------- VCX version 7.1.xc is now available -------------------
VCX S
S
ERVER
OFTWARE
e The
Do you want to continue with the above settings? [n/y]:
prompt appears.
Enter
to continue. The script executes.
y
5 Enter the following command to exit the cworks account and return to
the root account:
exit
6 Obtain a copy of the
and place it in the
and Directory server. The variable
(for example,
vcx-all-7.0.3c.tar)
The letter
is always appended to the version number.
c
7 Enter these commands:
cd /opt/installtemp
tar xvf vcx-dataserver-7.1.xc.tar
cd upgrade-7.1.x
./install-upgrade
The system may prompt you to confirm that a new operating system
version will be installed and indicates which disk partition will be used
after the upgrade. If you see such a prompt, answer y.
The system displays several status messages. The last two messages are:
8 Change to the new software version by entering this command:
vcx-switchversion 7.1.xc
The system displays several status messages and provides prompts that
allow you enable UPS Monitoring.
9 The UPS Monitoring prompt appears:
An Uninterruptible Power Supply (UPS) can be used with VCX
systems to avoid disruption due to a power outage.
provides a UPS monitoring service which tracks the UPS's
status and performs a safe shutdown when the its battery is
depleted during a long power outage.
you must have a compatible UPS installed and configured in
accordance with the VCX documentation.
Enable UPS monitoring? [N]
F
V7.0
V7.1
ROM
TO
vcx-dataserver-7.1.xc.tar
directory on the Authentication
/opt/installtemp
indicates the version of VCX software
x
that will replace the current version.
software upgrade file
VCX
To use this feature,
: