6 The UPS Monitoring prompt appears:
7 After completing the Adhoc Conferencing and UPS Monitoring prompts,
8 After the system has completed the restart process, verify that the
9 Repeat steps 1 through 8 for all the other branch office servers in
Configuring UPS
Monitoring
Upgrading a Multi-Site VCX System with Branch Offices
Use the Adhoc service on this server? (Y/N) [Y]
If you want this server to act as a multi-caller (up to 6 callers)
conferencing server, enter
An Uninterruptible Power Supply (UPS) can be used with VCX
systems to avoid disruption due to a power outage.
provides a UPS monitoring service which tracks the UPS's
status and performs a safe shutdown when the its battery is
depleted during a long power outage.
you must have a compatible UPS installed and configured in
accordance with the VCX documentation.
Enable UPS monitoring? [N]
If you do not have a UPS installed and enter
remaining UPS configuration prompts are not displayed.
If you do have a UPS installed and enter
Monitoring
for information on the subsequent UPS configuration
prompts.
the server reboots. When the reboot process has been completed, the
system starts VCX 7.1.x services.
upgrade has occurred by entering this command:
ls -l /opt/3com/VCX
The symbolic link (VCX) should point to the new version of the VCX
software (7.1.xc). If the link does not point to the new version, wait a few
minutes and reenter the command. This could take several minutes and it
is important the link pointer is correct before proceeding.
Example Output
/opt/3com/VCX -> /opt/3com/VCX.7.1.xc
Region 2.
During the upgrade of a VCX server, you are asked if you want to enable
UPS monitoring. UPS monitoring can also be enabled after you upgrade
to VCX version 7.1 software. See
Support to an Existing VCX
monitoring.
. If not, enter
.
y
n
To use this feature,
n
and see
y
Chapter
8, especially
System, or more information on UPS
VCX
(or press Enter); the
Configuring UPS
Adding UPS
211
:
: