3Com VCX V7000 Maintenance Manual page 116

Ip telephony solution
Hide thumbs Also See for VCX V7000:
Table of Contents

Advertisement

116
C
7: R
HAPTER
ECONFIGURING A
Sample VCX Reconfiguration Script (continued)
The SNMP 'write' community string configured in the UPS is required.
security reasons, it is recommended that the default value provided by the
UPS be changed.)
UPS 'write' community string
Enter the IP address assigned to the second UPS's management card or
Ethernet interface.
address.
Second UPS IP address
The SNMP 'write' community string configured in the second UPS is required.
Second UPS 'write' community string
The VCX system polls the UPS at regular intervals to get status
information.
A shorter interval makes the system more responsive to UPS
status changes, but consumes more network bandwidth.
should work for most systems.
Polling Frequency (seconds)
A 'low battery' condition is reached when the battery charge reaches a
defined threshold percentage.
Low Battery Threshold (%)
Do you wish to change any of the UPS Monitoring parameters? [N] : n
VCX S
ERVER
The string you enter here must match the SNMP write community string
configured on the UPS.
Note: The UPS must already be configured with this
The string you enter here must match the SNMP write community string
configured on the UPS.
The default polling interval is 30 seconds.
Enter UPS battery threshold charge allowed before starting a shutdown
of the VCX system. The threshold charge is expressed as a percentage of
remaining battery power. The default is 25%. The range is from 25% to
75%.
(For
: private
: 10.230.67.51
: private
The default value
: 30
: 25