Installing A 1012T Mounting Track In Direct Mode - Siemens SITRANS FUH1010PVDX Operating Instructions Manual

Ultrasonic flowmeters ip65 nema 7 compact precision volume 7me3601-3
Table of Contents

Advertisement

Section 3
5. Once transducer is in place, secure with the transducer clamping screw. Do not overtighten. Observe
the upstream/downstream orientation and connect the transducer cable to the computer's input jack.
If a dual-channel unit, make sure you connect the cable to the input jacks of the correct channel.
Repeat this procedure for the number index transducer.

Installing a 1012T Mounting Track in Direct Mode

Paragraph 3.4 describes the installation procedures that lead up to the automatic selection of transduc-
ers, mounting mode and spacing method. Shown is a Model 1012T mounting track to accommodate
size B3 universal transducers. Examine the figure below which shows a typical Pick/Install Xdcr menu
screen. Note the automatic assignment of model numbers for the transducer and mounting track, plus
the designation of number index.
1. Perform all required menu steps up until the point where the flow computer prompts you to press
<ENT> to finish the transducer install routine. Note the reported number index.
You will be inserting an index pin into this hole and the reference hole. Check to ensure that you have
a matched set of transducers. They both should have the same S/N number but marked with either an
"A" or "B" (e.g., 100A and 100B).
2. The Direct mount configuration uses two track rails, one for each transducer, installed 180
the pipe. One track rail includes the tension screw while the other has a locating stud to support the
chain (see below and on next page).
Upstream
Transducer
TOP VIEW
INSTALLATION – DIRECT MOUNT 180º OPPOSED WITH MOUNTING TRACK
Siemens
2 Channel
Key [Install] after mounting transducers
Transducer Model
Transducer Size
Xdcr Mount Mode
Spacing Offset
Number Index
Spacing Method
Ltn Value (in)
Install Completed?
Empty Pipe Set
Zero Flow Adjust
Pick/Install Xdcr
Number
Index Pin
Downstream
Transducer
[1]
SITE1
1011 Universal
B3
Direct
Minimum
4
Track 1012TP
0.217
No
Channel Not Setup
Channel Not Setup
Transducer
Clamping Screw
Track Rails
3-17
CQO:1010PVXFM-3
Note selection of track
P/N, Mount Mode and
Number Index.
apart on
o
Chain
Tensioning
Screw

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sitrans fuh1010pvx

Table of Contents