Siemens SITRANS FUH1010PVDX Operating Instructions Manual page 61

Ultrasonic flowmeters ip65 nema 7 compact precision volume 7me3601-3
Table of Contents

Advertisement

Section 2
Terminal Mode Menu Commands
In addition to Menu, the following commands (followed by the <ENT> key) can be used to control the
flowmeter while in Terminal Mode.
Note that "n" refers to the flowmeter Channel number. For a dual channel Arithmetic site (Ch1 + Ch2 or
Ch1 – Ch2) the virtual Channel is number 3.
Logger – Invokes the download of all data stored in the datalogger. Note that the datalogger data is not
erased from the flowmeter memory when it is downloaded. It is recommended to capture this information
into a file with a "csv" extention, which can be easily imported into MS EXCEL.
SITE – Invokes a full site download for a single channel or multi-path flowmeter.
SITE "n" – Invokes a site download for channel "n", where "n" = the Channel # (1, 2, 3, 4, etc).
DP "n" – Commands the flowmeter to download the digitized receive signal data for Channel or Path
"n".
CLRTOT – Clears the Totalizer for a single channel or multi-path flowmeter.
CLRTOT "n" – Clears the Totalizer for Channel "n" of a multi-channel flowmeter.
Lf on – Turns on the Line Feed at the end of any text string sent by the flowmeter.
Lf off – Turns off the Line Feed at the end of any text string sent by the flowmeter.
? – Provides a list of available Terminal Mode meter commands.
Transfer of Information from a FUS1010/1020 Flowmeter to the PC
With HyperTerminal active:
1. Point to Transfers, and click.
2. Select Capture Text.
3. Select desired drive path or directory, enter a file name, and click the Start button.
4. Use the following conventions for data file names:
For site data or Waveshape data:
For Datalogger data:
5. On PC type the proper command for the data desired (Logger, Site, or DP) & [Enter].
6. The data should begin streaming on the HyperTerminal screen.
7. Wait for EOT (End OF Transmission) to be displayed.
8. Close the file by pointing to Transfer, drag to Capture Text and click Stop button.
Close the Terminal or HyperTerminal Program
You may now close the Terminal program. The file(s) you have downloaded are now saved in the
location you selected. You may now import the file you have saved into the appropriate program (i.e., MS
Word for site data, or MS Excel for Datalogger or Waveshape data for graphing or analysis).
filename.txt
filename.csv
2-23