Selecting Display Data Items - Siemens SITRANS FUH1010PVDX Operating Instructions Manual

Ultrasonic flowmeters ip65 nema 7 compact precision volume 7me3601-3
Table of Contents

Advertisement

Section 5
The scrolling Siemens Welcome Screen (i.e., if no channel had been previously activated), or
The active channel's last data screen displayed prior to turning off the instrument.
After successful channel installation, use the Magnetic Wand and repeatedly trigger <Left Arrow> com-
mands to leave the top level of the Installation Menu.
The display indicates data as follows (see figure below):
NOTE: The default display shows two lines of flowrate data.
First Character Field - Displays the channel number (e.g., 1 or 2).
Middle Character Field - Displays the numeric value of the data item selected.
Last Character Field - Provides a mnemonic of the data type currently displayed.
Channel Number
Selection Cursor
Although the list of available data items varies depending upon the model, the available data usually
includes those items seen in the [Flow Data] submenu of the [Diagnostics Data] menu.

Selecting Display Data Items

The arrow keys are used to select the item that is displayed on each line as follows:
Right Arrow – Upon activating the <Right Arrow> key with the Magnetic Wand, a selection cursor will
appear under one of the channel indicator numerals (i.e., 1, 2, or 3). Activating the <Right Arrow> once
again will cause the selection cursor to move to the other display line and so forth. (Note: The selection
cursor will extinguish by itself after a period of inactivity.)
Up/Down Arrows – Once a display line is selected as described above, use the <Up or Down Arrows>
to scroll the selected display line through the available data items. (Note: On two channel units the
channel selection indicator will change when the data items come from the other channel.)
When satisfied with the item currently displayed, stop scrolling and use the <Right Arrow> to move to the
other display line. Once the display is set up in the desired configuration, execute no further commands
and the selection cursor will eventually extinguish.
Note that the System Menu can be invoked at any time by activating the
Magnetic Wand.
The Data displays provided via the meter's serial interface mimic the other FUH1010 Family's more
elaborate graphic displays. Display selection is provided via the <Up/Down Arrows> only. The 2 x 16
alphanumeric display is not available via the serial port.
1
9.15 GAL
1
5.02 GAL/M
5-81
CQO:1010PVXFM-3