Step 3: Install the Transducers.
A. Apply a thin bead of CC128 to the bottom side of the transducers
along their center length. See Fig 3-1.
B.
Visually confirm the presence of insulating tape on the inside walls of
the housings. Insert Transducer into housing.
catch or compromise the insulating tape while inserting the
transducer.)
Secure the spacing strap as shown in Fig 3-2. Lift up on
spring clip to install.
C. Drop transducer into place. Install the cable. See Fig 3-3 and 3-3A. Fill
connector with CC110 grease prior to connection. Backfill the
protective boot and slide into place.
D. Install bracket at outside hinge. Bracket hooks over the hinge. See Fig
3-3 and 3-4.
E.
Drop bracket in place. See Fig 3-5.
F.
Slide forward to latch. See Fig 3-6.
G. Secure bracket by installing screw at hinged location. See Fig 3-7.
H. Tighten Clamping Screw to secure transducer. (Torque to 15 in/lbs)
Secure with hex nut. See Fig 3-8.
I.
Verify LTN by comparing the calculated value from the FDC to the
actual distance from transducer front face to transducer front face.
(transducer edge is visible at bottom of side plates.)
J.
Complete the make-up process and verify the operation of the
installation before continuing to final step. Adjustment of transducer
spacing may be required. If this is so, one of the housings for that path
must be repositioned to the re-specified spacing index.
Continue to Step 4
Fig 3-3A
Backfill
protective boot
with CC110
1012WS-7
Rev B
CC506 Rev A/-
Fig 3-1
(Note: Be careful not to
Fig 3-3
Fig 3-5
Fig 3-7
Insulating
Tape
Fill connector
with CC110
Fig 3-2
Fig 3-4
Drop
Bracket
Transducer
Hinge
in place
Fig 3-6
Fig 3-8
Install
retaining
screw
Bracket
hooks onto
hinge
Slide bracket forward
to latch under
opposite hinge.
Tighten to 15
in/lbs. Install
Locking Nut after
tightening.