Siemens SITRANS FUH1010PVDX Operating Instructions Manual page 287

Ultrasonic flowmeters ip65 nema 7 compact precision volume 7me3601-3
Table of Contents

Advertisement

Installation Instructions
1012WS-2-7
Inspection Proc
Test Proc
NA
Covered Assemblies:
1012WS Dual Enclosure (Reflect and Direct-X Modes)
Document Rev
A/-
A/1
Added provisions for welding to pipe (Page 8 Step 5)
A/2
B
Tools Required
1) Hex Key Set
2) Phillips Head Screwdriver
3) 7/16" Socket
4) 7/16" Wrench
5) Razor Blade
6) Flat Blade screwdriver
7)
Torque limiting driver/wrench
Compounds Used
1) CC128
2) CC110
CC-506
Form Rev A/-
Prep By
NA
G VanPopering
Change Description
Original Release
Fixed Typo Step 2 Paragraph A,C (Notes)
(CN5157) Changed LOGO to Siemens
S.A.E. 5/32 and 1/8 In.
#2
Deep throat
Open end
in/lbs
Super Lube
G662 Silicone Grease
Date
Approval
10/29/01
Engineering:
Valid By:
Change Log
Date
03/16/06
08/14/06
Pre Assembly Note:
1.
Using the installation menu and the procedure outlined in the FDC Field Manual, confirm
that you have the appropriate transducers and Enclosure Set for operation on the chosen
pipe.
2.
Select mounting location
2.1 Choose location that remains full at zero flow.
2.2 Where possible, locate enclosure ass'y 10 pipe diameters or more from elbow or valve to
ensure fully developed and stable flow profile.
2.3 On horizontal pipe sections, select horizontal plane to avoid sediment or gas blockage of
ultrasonic beam.
2.4 Multiple beam applications see drawing 1012WS-8 and/or Fig 1-1 of this procedure.
3.
Prepare pipe for enclosure mounting.
3.1 Remove grit, corrosion, coating or heavy paint. (Avoid grinding which could cause distortion
of the pipe surface
3.2 Clean and degrease surface.
3.3 Do not mount over frost.
3.4 Do not mount on the seam of the pipe.
3.5 Locally, smooth the pipe surface to accept the transducers. Use the abrasive pad provided.
(Note: It is recommended two people be available to perform
this procedure.)
Weld Seal Installation Instructions
Initial
DR
N/A
Change By
GV
GV
GV
GV
General Notes
1012WS-2-7
Date
03/22/06
N/A
Approved
DR
MF
Page 1 of 8

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sitrans fuh1010pvx

Table of Contents