Siemens SITRANS FUH1010PVDX Operating Instructions Manual page 290

Ultrasonic flowmeters ip65 nema 7 compact precision volume 7me3601-3
Table of Contents

Advertisement

Step 1-D: Mounting the Straps
A. Roughly Locate the Keepers on the horizontal plane of
the pipe. See Fig 1-11 and 1-12.
B. Using the Mylar material provided, make a template.
Tightly wrap the Mylar strip around the pipe and overlap
the ends. Cut off any excess. Temporarily tape the end
together. Mark the template with a marker where the
ends overlap. See Fig 1-13 and -1-14.
C. Remove the template. Align the mark with the other end
of the template and fold the Mylar while maintaining
alignment. Mark the seam with a marker.
the template out on a table you will observe that the
distance between marks is half the actual circumference
of the pipe).
See Fig 1-15 and 1-16.
D. Reinstall the template. Locate it next to one of the most
outer strap locations. Align the marks of the template to
the horizontal plane of the pipe. Now align the keepers,
on center, with the marks on the template. See Fig 1-17
and 1-18.
(Note: It is important to maintain alignment of
this set of keepers throughout the remaining process. This
is the reference point when mounting the housings and
aligning and manipulating the remaining Keepers.)
Continue to Step 2.
Fig 1-15
Align and
Fold
1012WS-2-7
Rev B
CC506 Rev A/-
For Direct-X Mode
(Note: If you lay
Fig 1-16
Distance is Half of
circumference
Fig 1-11
Keepers
Screw Lock
Buckle
Fig 1-13
Fig 1-17
Fig 1-12
Locate the keepers
along the horizontal
plane of the pipe
Fig 1-14
Mark
Fig 1-18
On center
with marks
Page 4 of 8

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sitrans fuh1010pvx

Table of Contents