Section 5
5.3.3 HOW TO SELECT A PIPE TEMPERATURE RANGE
This menu cell informs the flow computer about the expected temperatures that the transducers will be
subjected to during operation. The default setting, -30
ture range of our standard 991 or 1011 series transducers. The other selections provide higher upper
limits of 375
F and 450
0
If you know that the pipe temperature will exceed 250
this menu cell to select the appropriate range. This will allow the flow display computer to restrict its
transducer recommendations to the appropriate environmentally rated types.
To select a Temperature Range:
To access the [Temperature Range] option list press
To highlight the desired range press
To register your selection press
5.3.4 PIPE CONFIGURATION
The [Pipe Configuration] menu cell in the Application Data menu presents a list of descriptions of piping
configurations that could affect the flow profile characteristics (such as "Single Elbow"). Examine the
option list. Selecting a piping configuration that closely approximates conditions at or near your mounting
location allows the flow computer to compensate for the effect of upstream piping on flow profile. The
number of diameters between the upstream configurations and the transducer installation can be nu-
merically entered via the [Anomaly Diams] menu cell.
To select a Piping Configuration:
To access the [Pipe Configuration] option list press
To highlight the desired piping configuration press
To register selection press
The default pipe configuration (Fully Developed) wll cause the flowmeter to use the conventional Reynolds
Compensation Table when compensating for liquid flow profile behavior.
Pipe Configuration Menu Structure
Application Data
* Default
F respectively.
0
ENT
ENT
Pipe Configuration
(Change to Upstream
Piping)
Anomaly Diams
F to 225
F corresponds with the rated tempera-
0
0
F at the transducer mounting location, please use
0
Fully Developed*
1 Elbow
Dbl Elbow +
Dbl Elbow -
Valve
Expander
Reducer
Norm Entry
Header Inlet
Intrusions
xxxx (numeric entry)