The I/O Data Control Menu - Siemens SITRANS FUH1010PVDX Operating Instructions Manual

Ultrasonic flowmeters ip65 nema 7 compact precision volume 7me3601-3
Table of Contents

Advertisement

Section 5
NOTE: In single channel FUH1010PVX meters the Datalogger uses a compression scheme that
precludes backward scrolling.
Important point about Datalogger resources and dual-channel systems.
When logging data on both measurement channels simultaneously, the Datalogger stores re-
ports in a single common file. It is important that you select Site ID to appear on each line of
data so that you can always identify which channel generated the report.
5.9

THE I/O DATA CONTROL MENU

This menu becomes available after picking a Meter Type and Channel/Path.
Use this menu to assign functions for the meter's analog outputs and optional inputs. The [Analog Out
Setup] menu cell assigns functions to the meter's current, voltage and pulse rate outputs. Each menu
cell presents an option list of the available data items. In addition, you can set up the alarm relays, enable
and span the analog input ports.
Use this menu to
assign data functions
to analog outputs.
Use this menu to
assign alarm
functions to relay
outputs.
Siemens
2 Channel [1]
Assign Data to Analog Outputs
Analog Out Setup
Relay Setup
Analog Input Setup
I/O Data Control
5-60
CQO:1010PVXFM-3
Channel 1
Use this menu to enable
and span optional
analog inputs.