Siemens SITRANS FUH1010PVDX Operating Instructions Manual page 102

Ultrasonic flowmeters ip65 nema 7 compact precision volume 7me3601-3
Table of Contents

Advertisement

Section 4
TERM
Local Display
Menu
Menu Cell
NEGFLOW
NETFLOW
NOTOT
Number Index
Numeric Data
Numeric Entry
Numeric Keys
OpSys ROM
Option List
Parameter
POSFLOW
RTD
Site Name
Site Setup
Site Storage Memory
TOTCNT
Transducer
Register
Spacing Index
Vaer
Vps
Vs
Refers to the FUH1010PVX integral display screen.
Sub-sections of the Installation Menu that you to define specific operational
functions (e.g., RS-232 Setup).
A location within a Menu where you define either a single numeric value or
option list selection that supports the Sub-Menu's function. Certain view-only
menu cells show reference data appropriate to the current application.
Totalizer mode for negative flow total only.
Totalizer mode that combines positive and negative flow totals.
System function that disables the internal Totalizer.
Computed transducer spacing index based on the estimated sonic velocity
measurement. This Index cannot be overridden by installer.
Refers to a value entered into a menu cell. An example would be the pipe
outer diameter.
Refers to a number you type into menu cell that stores numeric data.
Use the numeric keys to type a numeric value where appropriate.
The read only memory that stores its basic operating instructions and
permanent defaults.
Lists of options presented at menu cells that allow you to select a either a
single item or multiple items (depending on the function that the menu cell
controls).
Refers to value (either numeric or list selection) stored in a menu cell.
Totalizer mode for positive flow total only.
Temperature sensors used with energy flow of mass flow systems.
A user-entered name that meter associates with a stored Site Setup.
You retreive a particular Site by selecting its name from a site name list.
A collection of parameters used by the meter to service a specific site
(or location). Meter allows you to store several independent Site Setups.
Section of RAM allocated for permanent data storage. This memory
segment stores inactive site setups (including a backup of active site).
The meter's Site Setup storage capacity depends on the dynamic memory
allocation as dictated by each application. In addition, the flowmeter uses
Site Storage Memory to store configurable operating parameters such as
pipe and liquid tables.
A totalizer pulse count function used for Batching or Sampling.
Clamp-on flow sensors that the meter uses to measure the flow rate.
Refers to a memory location used by the flow displaycomputer to store data
such as the flow total, etc.
Refers to the Number Index, used by the flow display computer to determine
the space between the upstream and down stream transducers on clamp-on
systems.
The meter's aeration percent output.
The sonic propagation velocity of a pipe.
The sonic velocity of a liquid.
4-12
EXPLANATION
CQO:1010PVXFM-3