Section 5
Low Flow
The [Low Flow] menu cell stores the minimum range for the analog span.
To set the Low Flow alarm value:
To activate numeric entry press
Use the numeric keys or Magnetic Wand to type the Low Flow value.
To store the data press
The following Alarm Relay Setpoints are set in the same way as the two previously shown examples by
entering numeric values and storing the data.
High Liquident
The [High Liquident] menu cell sets the High Liquident alarm relay setpoint. The relay is used to differen-
tiate between liquids in the pipeline.
Low Liquident
The [Low Liquident] menu cell sets the Low Liquident alarm relay setpoint. The relay is used to differen-
tiate between liquids in the pipeline.
High Viscosity cS
The [High Viscosity cS] menu cell sets the high liquid viscosity alarm relay setpoint. The viscosity units are
centistokes with no alternatives offered.
Low Viscosity cS
The [Low Viscosity cS] menu cell sets the low liquid viscosity alarm relay setpoint. The viscosity units are
centistokes with no alternatives offered.
High Temperature
The [High Temperature] menu cell sets the high temperature alarm relay setpoint. If metric preferences
are selected prior to site creation the temperature units will be in Centigrade. If English preferences are
selected prior to site creation the temperature units will be in Fahrenheit.
Low Temperature
The [Low Temperature] menu cell sets the low temperature alarm relay setpoint If metric preferences
are selected prior to site creation the temperature units will be in Centigrade. If English preferences are
selected prior to site creation the temperature units will be in Fahrenheit.
Interface Vs m/s
The [Interface Vs m/s] menu cell sets the Interface Vs alarm relay setpoint. Relay changes state when
variable exceeds users setpoint.
ENT
5-51
CQO:1010PVXFM-3