Section 5
5.

THE FUH1010PVX INSTALLATION MENU

Programming the FUH1010PVX requires no special experience or training. This field manual contains all
the necessary information. If you intend to connect this instrument to an external device, then please
have the instruction manual for the device available for reference. The following paragraphs present a
generic menu reference that applies to all configurations of the FUH1010PVX NEMA flowmeters.
This section contains a general description of how to enter site setup data via the FUH1010PVX Installa-
tion Menu. It assumes that you have already selected a meter type as described in the Getting Started
section. For convenience, it presents the Installation Menu in the same sequence as it appears on the
menu screen. Please note, however, that it is not necessary to program the meter sequentially. Refer to
Section 2 to see how the Installation Menu appears on the 2x16 Character LCD Panel Display. In addition,
refer to Section 2 for a general description of how to enter data and how to complete a basic Site Setup.
The conventions used with these instructions are:
When the text refers to a sensor or keyboard key, it will be enclosed in "less than" (<) and "greater
than" (>) symbols (e.g., <MENU>, <ENT>, <Up Arrow>, etc).
Where a visual of the key is shown; this means press this key.
When the text refers to a menu or menu cell name, it will be enclosed with square brackets: e.g.,
[Pipe Data], [Channel Enable], etc.
Each menu includes an image of its main screen and a diagram of its structure. The rightmost
column of the structure diagram lists the option list choices of the menu cell, if applicable.

General Installation Menu Notes

If a power failure occurs while you are entering or editing data, the entered data may not be retained
in Active Memory.
Although you can operate the meter immediately after completion of the site setup, we recommend
that you preserve your settings by saving them under a site name. Site data can be saved at any
time before invoking either the [Recall Site Setup] or the [Create/Rename Site] commands. When
issued, these commands overwrite all data present in Active Memory. The meter will prompt you to
save your site each time you leave the menu.
The meter allows you to create your own personal site setup defaults. After creating a site setup and
editing default parameters as desired, save the site using the name [FASTSTRT]. The next time you
issue the [Create/Name Site] command, your custom parameters will become the system's de-
faults.
We do not recommend that you attempt to operate the flowmeter at a new site by recalling and then
editing an existing site setup. Each site must have its own set of transducer installation parameters,
even if the data from the recalled site setup is identical.
Always issue the [Create/Name Site] command to begin a new site setup. This will fill all the menu
cells with defaults to eliminate the possibility of retaining unwanted parameters.