AudioCodes Mediant 1000 User Manual page 818

Enterprise session border controller (e-sbc) and media gateway
Hide thumbs Also See for Mediant 1000:
Table of Contents

Advertisement

Parameter
IP Group
ip-group-name
[PerformanceProfile_IPGroupName]
SRD
srd-name
[PerformanceProfile_SRDName]
PM Type
pmtype
[PerformanceProfile_PMType]
Action
Minor Threshold
minor-threshold
[PerformanceProfile_MinorThreshold]
Major Threshold
major-threshold
[PerformanceProfile_MajorThreshold]
Hysteresis
hysteresis
[PerformanceProfile_Hysteresis]
User's Manual
'SRD' parameter (see below).
[2] IP Group = Assigns an IP Group. To specify the IP
Group, use the 'IP Group' parameter (see below).
Assigns an IP Group to the rule.
Note: The parameter is applicable only if you configure the
'Entity' parameter to IP Group.
Assigns an SRD to the rule.
Note: The parameter is applicable only if you configure the
'Entity' parameter to SRD.
Defines the type of performance monitoring metric for which
you want to configure thresholds.
[16] ASR (Default)
[17] ACD
[18] NER
Defines the Minor threshold (in percentage) of the selected
performance monitoring metric, which is the lower threshold
located between the Yellow and Green states.
To consider a threshold crossing:
Increase in severity (i.e., Green to Yellow): Only this
value is used.
Decrease in severity (Red to Green, or Yellow to
Green): This value is used with the hysteresis, configured
by the 'Hysteresis' parameter (see below).
The valid range is 0 to 100. The default is 0.
Defines the Major threshold (in percentage) of the selected
performance monitoring metric, which is the upper threshold
located between the Yellow and Red states.
To consider a threshold crossing:
Increase in severity (i.e., Yellow to Red, or Green to
Red): Only this value is used.
Decrease in severity (Red to Yellow): This value is
used with the hysteresis, configured by the 'Hysteresis'
parameter (see below).
The valid range is 0 to 100. The default is 0.
Defines the amount of fluctuation (hysteresis) from the
configured threshold in order for the threshold to be
considered as crossed. Hysteresis is used to avoid false
reports being sent by the device. Hysteresis is used only
when the severity level decreases (i.e., from Red to Yellow,
Yellow to Green, or Red to Green).
The valid value is 0 to 15 (in percentage). The default is 5.
For example, if you configure the 'Major Threshold'
parameter to 70% and the 'Hysteresis' parameter to 2%, the
device considers a threshold crossing from Red to Yellow
only if the ASR crosses 72% (i.e., 70% + 2%).
818
Mediant 1000B Gateway & E-SBC
Description
Document #: LTRT-27045

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents