User's Manual
Parameter
Display Last Login Information
[DisplayLoginInformation]
[EnableMgmtTwoFactorAuthentication] Enables Web login authentication using a third-party, smart
http-port
[HTTPport]
[DisableWebConfig]
[ResetWebPassword]
Version 7.2
62. Configuration Parameters Reference
expires can users attempt to login from this same IP
address.
The valid value is 0 to 100000, where 0 means that login is
not denied regardless of number of failed login attempts.
The default is 60.
Enables display of user's login information on each
successful login attempt.
[0] Disable (default)
[1] Enable
card.
[0] = Disable (default)
[1] = Enable
When enabled, the device retrieves the Web user's login
username from the smart card, which is automatically
displayed (read-only) in the Web Login screen; the user is
then required to provide only the login password.
Typically, a TLS connection is established between the
smart card and the device's Web interface, and a RADIUS
server is implemented to authenticate the password with the
username. Thus, this feature implements a two-factor
authentication - what the user has (the physical card) and
what the user knows (i.e., the login password).
Defines the LAN HTTP port for Web management. To
enable Web management from the LAN, configure the
desired port.
The default is 80.
Note: For the parameter to take effect, a device reset is
required.
Determines whether the entire Web interface is read-only.
[0] = (Default) Enables modifications of parameters.
[1] = Web interface is read-only.
When in read-only mode, parameters can't be modified and
the following pages can't be accessed: Web User Accounts,
TLS Contexts, Time and Date, Maintenance Actions, Load
Auxiliary Files, Software Upgrade Wizard, and Configuration
File.
Note: For the parameter to take effect, a device reset is
required.
Resets the username and password of the primary ("Admin")
and secondary ("User") accounts to their default settings
("Admin" and "Admin" respectively), and deletes all other
users that may have been configured.
[0] = (Default) Password and username retain their
values.
[1] = Password and username are reset.
Note:
For the parameter to take effect, a device reset is
929