AudioCodes Mediant 1000 User Manual page 1176

Enterprise session border controller (e-sbc) and media gateway
Hide thumbs Also See for Mediant 1000:
Table of Contents

Advertisement

Parameter
Answer Machine Detector Beep
Detection Timeout
configure voip > media ipmedia >
amd-beep-detection-timeout
[AMDBeepDetectionTimeout]
Answer Machine Detector Beep
Detection Sensitivity
configure voip > media ipmedia >
amd-beep-detection-sensitivity
[AMDBeepDetectionSensitivity]
early-amd
[EnableEarlyAMD]
AMD mode
configure voip > sip-definition
settings > amd-mode
[AMDmode]
Energy Detector Parameters
Enable Energy Detector
configure voip > media ipmedia >
energy-detector-enable
[EnableEnergyDetector]
Energy Detector Quality Factor
configure voip > media ipmedia >
energy-detector-sensitivity
[EnergyDetectorQualityFactor]
Energy Detector Threshold
configure voip > media ipmedia >
energy-detector-threshold
User's Manual
[2] Start Immediately
Defines the AMD beep detection timeout (i.e., the duration that
the beep detector functions from when detection is initiated).
This is used for detecting beeps at the end of an answering
machine message.
The valid value is in units of 100 milliseconds, from 0 to 1638.
The default is 200 (i.e., 20 seconds).
Defines the AMD beep detection sensitivity for detecting beeps
at the end of an answering machine message.
The valid value is 0 to 3, where 0 (default) is the least sensitive.
Enables AMD detection to be activated upon receipt of an
ISDN Alerting or Connect message.
[0] = (Default) Disable - AMD is activated upon receipt of
ISDN Connect message.
[1] = Enable - AMD is activated upon receipt of ISDN
Alerting message.
Note: The parameter is applicable only to digital interfaces.
Global parameter that enables the device to disconnect the IP-
to-Tel call upon detection of an answering machine on the Tel
side. You can also configure this functionality per specific calls,
using IP Profiles (IpProfile_AmdMode). For a detailed
description of the parameter and for configuring this
functionality in the IP Profiles table, see ''Configuring IP
Profiles'' on page 393.
Note: If this functionality is configured for a specific IP Profile,
the settings of this global parameter is ignored for calls
associated with the IP Profile.
Enables the Energy Detector feature. This feature generates
events (notifications) when the signal received from the PSTN
is higher or lower than a user-defined threshold (defined by the
EnergyDetectorThreshold parameter).
[0] Disable (default)
[1] Enable
Defines the Energy Detector's sensitivity level.
The valid range is 0 to 10, where 0 is the lowest sensitivity and
10 the highest sensitivity. The default is 4.
Defines the Energy Detector's threshold. A signal below or
above this threshold invokes an 'Above' or 'Below' event.
The threshold is calculated as follows:
1176
Mediant 1000B Gateway & E-SBC
Description
Document #: LTRT-27045

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents