Thank you for purchasing a PowerPad
For best results from your instrument and for your safety, read the enclosed operating instructions carefully and comply with the
precautions for use. These products must be only used by qualified and trained users.
WARNING, risk of DANGER! The operator must refer to
these instructions whenever this danger symbol appears.
CAUTION! Risk of electric shock. The voltage at the
parts marked with this symbol may be dangerous.
Equipment is protected by double insulation.
USB socket.
Ground/Earth.
Must not be applied to or removed from bare
conductors carrying dangerous voltages. Type B
current sensor as per EN 61010-2-032.
Application or withdrawal authorized on conductors
carrying dangerous voltages. Type A current sensor per
IEC 61010-2-032.
Definition of Measurement Categories (CAT)
■ CAT IV
Measurement category IV corresponds to measurements taken at the source of low-voltage installations.
Example: power feeders, counters and protection devices.
■ CAT III
Measurement category III corresponds to measurements on building installations.
Example: distribution panel, circuit-breakers, machines or fixed industrial devices.
■ CAT II
Measurement category II corresponds to measurements taken on circuits directly connected to low-voltage installations.
Example: power supply to domestic electrical appliances and portable tools.
This instrument is compliant with safety standard IEC 61010-2-030, the leads are compliant with IEC 61010-031, and the current
sensors are compliant with IEC 61010-2-032, for voltages up to 600V in category IV or 1000V in category III. Failure to observe the
safety instructions may result in electric shock, fire, explosion, and destruction of the instrument and/or other equipment.
● The operator and/or the responsible authority must carefully read and clearly understand the various precautions for use of
the instrument. Sound knowledge and a keen awareness of electrical hazards are essential when using this instrument.
● If you use this instrument other than as specified, the protection it provides may be compromised, thereby endangering you.
● Do not use the instrument on networks which the voltage or category exceeds those mentioned.
● Do not use the instrument if it appears damaged or otherwise compromised.
● Before each use, check the condition of the insulation on the leads, housing, and accessories. Any item on which the
insulation is deteriorated (even partially) must be set aside for repair or scrapping.
● Before using your instrument, check that it is perfectly dry. If it is wet, it must be thoroughly dried before being connected or
being operated in any way. This includes the terminals and keypad.
● Use only the leads and accessories supplied. Using leads (or accessories) of a lower voltage or category reduces the voltage
or category of the combined instrument and leads (or accessories) to that of the leads (or accessories).
● Always use personal protection equipment.
● Keep your hands away from the terminals of the instrument.
● When handling the leads, test probes, and alligator clips, keep your fingers behind the physical guard.
● Use only the AC power cord and battery pack supplied by the manufacturer. They include specific safety features.
● Some current sensors must not be placed on or removed from bare conductors at hazardous voltages: refer to the manual
and comply with the handling instructions.
III Model 8336
®
PRECAUTIONS FOR USE
Useful information or hint to read.
Important instructions to read and to fully understand.
Kensington anti-theft system.
The product has been declared recyclable after analysis of
its life cycle in accordance with the ISO14040 standard.
The CE marking guarantees conformity with European
directives and with regulations covering EMC.
The trash can with a line through it means that in the
European Union, the product must undergo selective
disposal for the recycling of electric and electronic
material, in compliance with Directive WEEE 2002/96/EC.