8.2 KEYPAD BUTTONS

8.2.1 FUNCTION BUTTONS (YELLOW BUTTONS)

These six buttons activate the function or tool represented by the corresponding icon on the screen.

8.2.2 NAVIGATION BUTTONS

A block of four arrow buttons, a select button and a return button are available for navigating menus.
Button
Function
Up direction or navigation button.
Down direction or navigation button.
Right direction or navigation button.
Left direction or navigation button.
Confirms the selection.
Return button.

8.2.3 MODE BUTTONS (VIOLET BUTTONS)

These buttons provide access to specific modes:
Button
Function
Waveform acquisition mode, with two sub-modes: transients mode (blackouts, interference,
etc.) and inrush current mode (starting of motor).
Harmonic display mode: displays voltage, current, and power harmonics, order by order;
determination of harmonic currents produced by nonlinear loads, analysis of problems caused
by harmonics according to their order (overheating of neutrals, conductors, motors, etc.).
Voltage and current waveforms mode, display of minima and maxima of summary tables,
determine phase rotation.
Alarm mode: list recorded alarms exceeding the thresholds programmed in the configuration;
record network blackouts with half-cycle resolution (Vrms, Arms, Urms), determine energy
consumption overshoots, monitor compliance with a power supply quality contract.
Trend mode: record parameters selected in the Configuration menu.
Power and energy measurements
Three of these buttons are real-time mode buttons:
a white ground (for example
is colored when the channel measured is potentially full (for instance
When a numbered circle corresponds to a simulated channel (for example in 4-wire 3-phase with selection V1V2,
2½-element method, or in 3-wire 3-phase with selection A1A2, 2-element method) this channel is potentially full if at
least one channel used in calculating it is potentially full. Similarly, if the circle corresponds to a phase-to-phase voltage
channel, it is potentially full if at least one of the phase-to-neutral voltage channels used in calculating it is potentially full.
Power Quality Analyzer PowerPad
) in which the channel numbers or types appear indicate saturation: the ground of the circle
III Model 8336
®
,
, and
. In each of these modes, the colored circles on
.
)
See
§ 5.1
§ 5.2
§ 5.3
§ 5.4
§ 5.5
§ 5.6
113