124
Measurement range
(with unity ratio)
Minimum
Maximum
2V
1000V
(1)
2V
2000V
(2)
2V
1000V
(1)
2V
2000V
(2)
1A
3500A
1A
1000A
200mA
200A
100mA
100A
10mA
10A
5mA
5A
10A
10kA
10A
6500A
100mA
100A
Display resolution
(with unity ratio)
100 mV
V < 1000V
1V
V ≥ 1000V
100 mV
U < 1000V
1V
U ≥ 1000V
100 mV
V < 1000V
1V
V ≥ 1000V
100 mV
U < 1000V
1V
U ≥ 1000V
1A
100mA
A < 1000A
1A
A ≥ 1000A
100mA
10mA
A < 100A
100mA
A ≥ 100A
1mA
A < 10A
10mA
A ≥ 10A
1mA
1A
±(2% + (n x 0.3%) + 1A + (Af
A < 10kA
10A
±(2% + (n x 0.6%) + 1A + (Af
*
A ≥ 10kA
100mA
±(2% + (n x 0.3%) + 1A + (Af
A < 1000A
1A
±(2% + (n x 0.6%) + 1A + (Af
A ≥ 1000A
10mA
A < 100A
100mA
A ≥ 100A
Power Quality Analyzer PowerPad
Maximum intrinsic accuracy
±(2.5% + 1V)
±(2.5% + 1V)
±(2.5% + 1V)
±(2.5% + 1V)
±(2% + (n x 0.2%) + 1A)
n ≤ 25
±(2% + (n x 0.2%) + 1A)
n ≤ 25
±(2% + (n x 0.5%) + 1A)
n > 25
±(2% + (n x 0.2%) + 1A)
n ≤ 25
±(2% + (n x 0.5%) + 1A)
n > 25
±(2% + (n x 0.2%) + 100mA)
n ≤ 25
±(2% + (n x 0.5%) + 100mA)
n > 25
±(2% + (n x 0.2%) + 10mA)
n ≤ 25
±(2% + (n x 0.5%) + 10mA)
n > 25
±(2% + (n x 0.2%) + 10mA)
n ≤ 25
±(2% + (n x 0.5%) + 10mA)
n > 25
x 0.1%))
(3)
rms
n ≤ 25
x 0.1%))
(3)
rms
n > 25
(3)
x 0.1%))
rms
n ≤ 25
x 0.1%))
(3)
rms
n > 25
±(2% + (n x 0.2%) + 30cts)
n ≤ 25
±(2% + (n x 0.5%) + 30cts)
n > 25
III Model 8336
®