Technical Data

Parameter
Front panel, W x H x D 382 x 252 x 6 mm
Mounting depth
Front panel seal
Rear panel seal
Keyboard material
Reverse side material
Weight
Serial port RS422/
RS485
Serial port RS232C
Ethernet
USB
CF-slot
Flash memory for
application
Real time clock
Power consumption at
rated voltage
Display
Active area of display,
W x H
Fuse
Power supply
Ambient temperature
Storage temperature
Relative humidity
EMC tests on the
operator terminal
UL, cUL approvals
* See section Chemical Resistance for keyboard and display
Mitsubishi Electric, MA00778A
58 mm (158 mm including clearance)
IP 66
IP 20
Membrane switch keyboard with metal domes. Overlay film
of Autotex F157 * with print on reverse side. 1 million
operations.
Powder-coated aluminum
2.3 kg
25-pin D-sub contact, chassis-mounted female with
standard locking screws 4-40 UNC.
9-pin D-sub contact, male with standard locking screws 4-40
UNC.
Shielded RJ 45
Host type A, power consumption max. 500mA
Device type B
Compact flash, type I and II
4 MB
±20 PPM + error because of ambient temperature and supply
voltage.
Total max error: 1 min/month at 25 °C
Minimum life of the real time clock battery: 3 years
Temperature coefficient: 0.004 ppm/°C
Normal: 0.5 A
Maximum: 1.0 A
TFT-LCD. 800 x 600 pixels, 64K color.
CCFL backlight lifetime at the ambient temperature of
+25 °C: 50,000 h.
211.2 x 158.4 mm
Internal DC fuse, 3.15 AT, 5 x 20 mm
+24V DC (20 - 30V DC). 3-pin jack connection block.
CE: The power supply must conform with the requirements
for SELV or PELV according to IEC 950 or IEC 742.
UL: The power supply must conform with the requirements
for class II power supplies.
Vertical installation: 0 ° to +50 °C
Horizontal installation: 0 ° to +40 °C
-20 ° to +70 °C
5 - 85 % non-condensed
The operator terminal conforms with the essential protection
requirements in article 4 of the directive 89/336/EEC. Noise
tested according to EN6100-6-4 emission and EN61000-6-2
immunity.
Certification in progress