5. Service Tables
TonerEndJudg
This SP code determines whether the machine disables printing when the machine detects
toner end.
3927
[0 to 1/0/1]
0: Yes (Printing stops when toner end is detected.)
1: No (Printing can continue even after toner end is detected.)
SP5-xxx: Mode
5
mm/inch Display Selection
Selects the unit of measurement.
5024
After selection, turn the main power switch off and on.
0: Europe/Asia (mm), 1: North America (inch)
Toner Refill Displ
This SP switches on/off the message that prompts the operator when it is necessary to
5051
replenish toner in the machine.
0: enable (Message displayed (Default))
1: disable (Message not displayed)
Display IP add
Switches the banner display of the IP address off and on.
[0 to 1/0/1] 0= No, 1= Yes
5055
For example, if this SP is switched on, the IP address will be displayed below "Ready"
while the printer is in standby mode:
Ready
169.254.187.055
5302
Set Time
92
• Even when toner end is detected, there is a small amount of toner left in the AIO. If
a user wants to print with the AIO until all toner is used up, then set this SP to 1. But
then, there is no toner end detection, and the user must watch the print quality and
change the AIO when prints become too pale.
Toner Refill Detect Display
Display IP Address