Due to a control error, a RAM overflow
occurred during system processing.
One of the following messages was
displayed on the operation panel.
0x696e
0x766d
4361
Other
For more details about this SC code error, execute SP5990 to print an SMC report so you can read the
error code. The error code is not displayed on the operation panel.
Self-Diagnostic Error: CPU
820
D
The central processing unit returned an error during the
self-diagnostic test.
Self-diagnostic error 2: ASIC
The ASIC provides the central point for the
control of bus arbitration for CPU access,
821
D
for option bus and SDRAM access, for
SDRAM refresh, and for management of
the internal bus gate.
For more details about this SC code error, execute SP5990 to print an SMC report so you can read the
error code. The error code is not displayed on the operation panel.
822
B
Self-diagnostic error 3: HDD
3003
init died
vm_pageout: VM is full
Cache Error
Check performed when HDD is installed:
HDD device busy for over 31 s.
After a diagnostic command is set for Sthe
HDD, but the device remains busy for over 6
s.
• System program defective
• Controller board defective
• Optional board defective
• Replace controller firmware
• Controller board defective
• Software defective
• ASIC (controller board defective)
• HDD defective
• HDD harness
disconnected, defective
• Controller board defective
Service Call Conditions