4. Troubleshooting
Just before reaching warm-up temperature,
the fusing temperature did not rise above
80
switched on.
Fusing overheat error – software
543
A
The fusing temperature was detected higher
than 235
High temperature detection: Hard
4
544
A
The thermister detects a high temperature
signal.
Fusing lamp remains on
The fusing lamp remained on longer than 12
545
A
sec. after the fusing unit reached optimum
temperature and the main motor switched off.
Unstable fusing temperature
During standby, the fusing temperature went
below 60 °C twice or went above 60 °C three
546
A
times within 500 ms.
A 60°C increase in fusing temperature was
detected at five 1-sec. intervals within 60 sec.
before reaching fusing temperature.
Zero cross signal error
Zero cross signals of wavelength 50-60 Hz
were not detected within 5 sec after the fusing
547
B
relay switched on.
-or-
Zero cross interrupts did not issue at the
prescribed 3 sec. intervals.
58
o
C within 15.5 sec. after the power relay
o
C for longer than 200 ms.
• Fusing thermostat open
• Power supply board Defective
• Defective connection of the fusing
unit
• Fusing thermistor defective
• Power supply board defective
• Defective thermister
• Defective fusing unit, PSU, engine
board
• Fusing thermistor defective
• Power supply board defective
• Defective connection of the fusing
unit
• Fusing thermistor defective
• Power supply board defective
• Defective connection of the fusing
unit
• Power supply board defective
• Defective mains power supply
condition