5-6. STATS MODE

June 2008
This mode allows a technician to view advanced information on
the operation of the fryer and controls.
1. To enter the TECH Mode, press and hold
buttons for 5 seconds, until display shows "LEVEL 3",
followed by "ENTER CODE".
2. Enter code 1, 1, 2, 2, 1, 1, 2, 2 (first 2 product buttons).
"A. TECH" & "RESETS" show in the displays.
3. Press
6 times, and when display shows "G. STATS", press
the right √ button and "ST-1 LAST RESET ON..." shows in
display, the first step of the TECH Mode. Use and
buttons to toggle through the steps.
ST-1
• Stats Last Reset Date
ST-2
• Fryer Total Running Hours
ST-3
• Left Vat Melt Cycle Hours
ST-4
• Left Vat Cook Cycle Hours
ST-5
• Left Vat Filter Lockout Hours
ST-6
• Right Vat Melt Cycle Hours
ST-7
• Right Vat Cook Cycle Hours
ST-8
• Right Vat Filter Lockout Hours
ST-9
• Power-Ups Count
ST-10 • Error Counts
ST-11 • Left Vat Heat On Hours
ST-12 • Right Vat Heat On Hours
ST-13 • Highest Left Vat Oil Temperature
ST-14 • Highest Right Vat Oil Temperature
ST-15 • Highest CPU Temperature
ST-16 • System RAM Fade Count
ST-17 • Cook RAM Fade Count
ST-18 • Product RAM Fade Count
ST-19 • Stat RAM Fade Count
ST-20 • RAM Data Error Count
ST-21 • Data Total Loss Count
ST-22 • User Intialization Count
ST-23 • Automatic Initialization Count
ST-24 • Cooks Count per Product
ST-25 • Cook Cycle Stop Counts
- "A" = number of stops in the first 30 seconds
- "B" = 0
- "C" = 0
- "D" = complete cook cycles counted
ST-26 • Reset All Stats
5-12