Lenze SCL series Installation And Operaion Manual page 33

Hide thumbs Also See for SCL series:
Table of Contents

Advertisement

NO.
PARAMETER NAME
TB-13E INPUT
FUNCTIONS
12
TB-13E OUTPUT
FUNCTIONS
OTHER FUNCTIONS
14
CONTROL
16
UNITS EDITING
17
ROTATION
19
ACCELERATION TIME
20
DECELERATION TIME
21
DC BRAKE TIME
22
DC BRAKE VOLTAGE
23
MINIMUM FREQUENCY
24
MAXIMUM FREQUENCY
25
CURRENT LIMIT
26
MOTOR OVERLOAD
27
BASE FREQUENCY
28
FIXED BOOST
29
ACCEL BOOST
RANGE OF ADJUSTMENT
NONE (01), 0-10 VDC (02), 4-20 mA (03),
PRESET SPEED #3 (04), INCREASE FREQ (05),
START FORWARD (06), EXTERNAL FAULT (07),
INVERSE EXT FAULT (08), AUX. STOP (09),
ACCEL/DECEL #2 (10),
RUN (11), FAULT (12), INVERSE FAULT (13),
FAULT LOCKOUT (14), AT SET SPEED (15),
ABOVE PRESET #3 (16), CURRENT LIMIT (17),
AUTO SPEED (18), REVERSE (19),
DYNAMIC BRAKING (20),
REMOTE KEYPAD (21)
TERMINAL STRIP ONLY (01)
REMOTE KEYPAD ONLY (02)
TENTHS OF UNITS (01), WHOLE UNITS (02)
FORWARD ONLY (01),
FORWARD AND REVERSE (02)
0.1 - 3600.0 SEC
0.1 - 3600.0 SEC
0.0 - 3600.0 SEC
0.0 - 30.0 %
0.0 - MAXIMUM FREQUENCY
MINIMUM FREQUENCY - 240 Hz
30 - 180 %
30 - 100 %
25.0 - 500.0 Hz
0.0 - 30.0 %
0.0 - 20.0 %
29
FACTORY
DEFAULT
NONE (01)
TERMINAL
STRIP ONLY
(01)
WHOLE
UNITS (02)
FORWARD
ONLY (01)
20.0 SEC
20.0 SEC
0.0 SEC
0.0 %
0.0 Hz
SCL = 50.0 Hz
SCM = 60.0 Hz
180 %
100 %
SCL = 50.0 Hz
SCM = 60.0 Hz
1.0 %
0.0 %
SM01M