Two-Wire Start/Stop Control
1
2
5
+
-
Maintained
RUN/STOP
Contact
(FORWARD)
NOTE
Close TB-1 to TB-11 to RUN, and open to STOP . TB-1 functons as a RUN
nput for two-wre start/stop crcuts, and a STOP nput for three-wre start/stop
crcuts . Refer to Secton 11 .3
If reverse drecton s requred, set ROTATION (Parameter 17) to FORWARD
AND REVERSE (02), and program TB-13A (Parameter 10) to RUN REVERSE
(06) . Close TB-13A to TB-11 to RUN n the reverse drecton, and open to
STOP .
For 0-10 VDC or 4-20 mA speed control, set STANDARD SPEED SOURCE
(Parameter 05) to 0-10 VDC (03) or 4-20 mA (04) .
6
11
13A
Maintained
RUN/STOP
Contact
(REVERSE)
2-Wre Start/Stop Control
13B
13E
25
+
19
FORM A RELAY
17
16
SM01M