Lenze Starttec E71MM402 Mounting Instructions

Lenze Starttec E71MM402 Mounting Instructions

Type 2 motor starter
Table of Contents

Advertisement

Available languages

Available languages

Show/Hide Bookmarks
EDK71MMXXX-020
!KJ9
L
Montageanleitung
Mounting Instructions
Instructions de montage
starttec
Motorstarter Typ 2
Type 2 motor starter
Démarreur moteur type 2

Advertisement

Table of Contents
loading

Summary of Contents for Lenze Starttec E71MM402

  • Page 1 Show/Hide Bookmarks EDK71MMXXX-020 !KJ9 Montageanleitung Mounting Instructions Instructions de montage starttec Motorstarter Typ 2 Type 2 motor starter Démarreur moteur type 2...
  • Page 2 2 = 205 VDC 4 = 180 VDC Ausführung x1x = Einzelantrieb x2x = Mehrmotorenbetrieb, Drehrichtungswechsel Hardwarestand Softwarestand Erst Montageanleitung lesen, dann mit den Arbeiten beginnen! Beachten Sie die enthaltenen Sicherheitshinweise. ã 2001 Lenze GmbH & Co KG Stand 1.0 09/2001 TD00...
  • Page 3 Show/Hide Bookmarks start209 ¶ 22 Anschluß Motor 1 [1U], [1V], [1W], [PE] [2U], [2V], [2W], [PE] Anschluß Motor 2 [L1], [L2], [L3], [PE] Netzanschluß ¶ 22 ¶ 24 [B1], [B2], [BN] Anschluß Federkraftbremse ¶ 25 Steueranschlüsse Stufenschalter zum Einstellen des Motornennstroms ¶...
  • Page 4 Mit [S] bzw. über C0120 den Nennstrom entsprechend dem angeschlossenen Motor einstellen. Die Betriebsart des starttec (C0014) muß unbedingt an die Verdrahtung angepaßt sein. Der starttec kann sonst zerstört werden: Zwei Motoren, eine Drehrichtung: C0014 = 0 (Lenze-Einstellung) Ein Motor, Drehrichtungswechsel: C0014 = 1!
  • Page 5: Table Of Contents

    ..........Lenze Niederspannungsmaschinen .
  • Page 6: Sicherheitshinweise

    Lenze-Motorstarter (gemäß Niederspannungsrichtlinie 73/23/EWG) 1. Allgemein Lenze-Motorstarter können während des Betriebs - ihrer Schutzart entsprechend - spannungsführende, auch bewegliche oder rotierende Teile haben. Oberflächen können heiß sein. Bei unzulässigem Entfernen der erforderlichen Abdeckung, bei unsachgemäßem Einsatz, bei falscher Installation oder Bedienung besteht die Gefahr von schweren Personen- oder Sachschäden.
  • Page 7 Show/Hide Bookmarks Sicherheitshinweise Motorstarter 5. Elektrischer Anschluß Beachten Sie bei Arbeiten an unter Spannung stehenden Motorstartern die geltenden nationalen Unfallverhütungsvorschriften (z. B. VBG 4). Führen Sie die elektrische Installation nach den einschlägigen Vorschriften durch (z. B. Leitungsquerschnitte, Absicherungen, Schutzleiteranbindung). Zusätzliche Hinweise enthält die Dokumentation. Die Dokumentation enthält Hinweise für die EMV-gerechte Installation (Schirmung, Erdung, Anordnung von Filtern und Verlegung der Leitungen).
  • Page 8: Lenze Niederspannungsmaschinen

    Show/Hide Bookmarks Sicherheitshinweise Lenze Niederspannungsmaschinen Allgemeine Sicherheits - und Anwendungshinweise für Lenze-Niederspannungsmaschinen (gemäß Niederspannungsrichtlinie 73/23/EWG) 1. Allgemein Niederspannungsmaschinen haben gefährliche, spannungsführende und rotierende Teile sowie möglicherweise heiße Oberflächen. Alle Arbeiten zu Transport, Anschluß, Inbetriebnahme und Instandhaltung sind von qualifiziertem, verantwortlichem Fachpersonal auszuführen (EN 50110-1 (VDE 0105-100); IEC 60364 beachten). Unsachgemäßes Verhalten kann schwere Personen- und Sachschäden verursachen.
  • Page 9 Show/Hide Bookmarks Sicherheitshinweise Lenze Niederspannungsmaschinen 5. Elektrischer Anschluß Alle Arbeiten dürfen nur von qualifiziertem Fachpersonal an der stillstehenden Niederspannungsmaschine im freigeschalteten und gegen Wiedereinschalten gesicherten Zustand vorgenommen werden. Das gilt auch für Hilfsstromkreise (z. B. Bremse, Geber, Fremdlüfter). Spannungsfreiheit prüfen! Überschreiten der Toleranzen in EN 60034-1;...
  • Page 10: Restgefahren, Gestaltung Der Sicherheitshinweise

    Show/Hide Bookmarks Sicherheitshinweise Restgefahren, Gestaltung der Sicherheitshinweise Restgefahren Personen- Schalten Sie vor Arbeitsbeginn / Öffnen des Gerätes den starttec spannungslos, da die schutz Leistungsanschlüsse L1, L2, L3, 1U, 1V, 1W, 2U, 2V, 2W, B1, B2 und BN gefährliche Span- nung führen: –...
  • Page 11 Show/Hide Bookmarks Sicherheitshinweise Restgefahren, Gestaltung der Sicherheitshinweise Gestaltung der Sicherheitshinweise Alle Sicherheitshinweise in dieser Anleitung sind einheitlich aufgebaut: (kennzeichnet die Schwere der Gefahr) Signalwort Hinweistext (beschreibt die Gefahr, gibt Hinweise, wie sie vermieden werden kann) verwendete Piktogramme Signalwörter Warnung vor Gefahr! Warnt vor unmittelbar drohender Gefahr.
  • Page 12: Technische Daten

    Show/Hide Bookmarks Technische Daten Allgemeine Daten Konformität Niederspannungsrichtlinie (73/23/EWG) EMV-Richtlinie (93/68/EWG) Normen DIN EN 60947-4-2 Halbleiter-Motor-Steuergeräte und -Starter für Wechsel- spannung Approbationen UL 508 Underwriter Laboratories (File-No. E132659) Power Conversion Equipment (in Vorbereitung) Rüttelfestigkeit Beschleunigungsfest bis 4g (Germanischer Lloyd, allgemeine Bedingungen) Klimatische Bedingungen Klasse 3K3 nach EN 50178 (ohne Betauung, mittlere relative Feuchte 85 %) Verschmutzungsgrad...
  • Page 13: Bemessungsdaten

    Show/Hide Bookmarks Technische Daten Bemessungsdaten Bemessungsdaten Motorschalter/Bremsenschalter 100 V –0 % ≤ UN ≤ 550 V +0 %; 45 Hz ... 65 Hz ±0 % Netzspannung Max. Ausgangsstrom 9.5 A Motorleistung bei Netzspannung 3 × 230 V P 0.25 ... 2.2 kW bei Netzspannung 3 ×...
  • Page 14 Show/Hide Bookmarks Technische Daten Bemessungsdaten Thermische Überwachung3. Gemäß DIN EN 60947-4-2 (Halbleiter-Motor-Steuergeräte und -Starter für Wechselspannung) ... schaltet der starttec ab Beträgt der Motorstrom das ... bei eingestellter x-fache des eingestellten fache des eingestellten A slöseklasse in C0121 Auslöseklasse in C0121 innerhalb von T Kriterium Ausgangsstroms in C0120 ...
  • Page 15 Show/Hide Bookmarks Technische Daten Bemessungsdaten Bemessungsdaten Steuerung Eigenschaft Klemme Spezifikation DC-Versorgung Steuerung X3/59 Spannung +18 VDC ... +30 VDC Stromaufnahme 200 mA bei 24 V (ohne Verbraucher an X3/20) Interne DC-Versorgung X3/20 +18 VDC ... +30 VDC, max. 500 mA Digitale Eingänge X3/28 HIGH aktiv...
  • Page 16: Abmessungen, Mechanische Ausführung

    Show/Hide Bookmarks Technische Daten Abmessungen, Mechanische Ausführung Abmessungen start001 a [mm] b [mm] c [mm] d [mm] e [mm] 228.0 10.0 104.5 129.0 71.0 Mechanische Ausführung Gehäuse Verschraubungen Gewicht Gehäuse mit Elektronikmodul aus Alumi- 4 × M20 (Gewindelänge 10 mm) nium-Druckguß...
  • Page 17: Motormontage

    Show/Hide Bookmarks Motormontage Lieferumfang Abb. 1-1 start010 Gehäuse mit Elektronikmodul Gehäusedeckel Distanz- und Wandplatte Dichtung Schrauben KA 50 × 18 für Wandmontage EDK71MMXXX-020 DE/EN/FR 1.0...
  • Page 18: Vorbereitung

    Show/Hide Bookmarks Motormontage Vorbereitung 3.4 Nm 30 lb-in 68-73mm Abb. 1-2 4 × 6 × start024 Schraube (DIN 7985) 20 mm Fächerscheibe nach DIN 6798 EDK71MMXXX-020 DE/EN/FR 1.0...
  • Page 19: Wandmontage

    Show/Hide Bookmarks Wandmontage Lieferumfang Abb. 1-3 start010 Gehäuse mit Elektronikmodul Gehäusedeckel Distanz- und Wandplatte Dichtung Schrauben KA 50 × 18 für Wandmontage EDK71MMXXX-020 DE/EN/FR 1.0...
  • Page 20: Vorbereitung

    Show/Hide Bookmarks Wandmontage Vorbereitung 5.3 mm 4 × 6 × Abb. 1-4 3.4 Nm 30 lb-in start022 Distanz- und Wandplatte Bohrbild Abstand a [mm] b [mm] c [mm] d [mm] e [mm] EDK71MMXXX-020 DE/EN/FR 1.0...
  • Page 21: Elektrische Installation

    Er253 (e). Die Betriebsart des starttec (C0014) muß unbedingt an die Verdrahtung angepaßt sein. Der starttec kann sonst zerstört werden: – Zwei Motoren, eine Drehrichtung: C0014 = 0 (Lenze-Einstellung) – Ein Motor, Drehrichtungswechsel: C0014 = 1! Sicherungen und Leitungsquerschnitte Leitungsquerschnitte und Sicherungen (träge) nach dem max. Eingangsstrom auslegen.
  • Page 22: Leistungsanschlüsse - Zwei Motoren

    Show/Hide Bookmarks Elektrische Installation Leistungsanschlüsse - Zwei Motoren Stop! Schließen Sie die Netzzuleitung phasenrichtig an. Wenn die Netzphasen an den Anschlußklemmen vertauscht sind, erfolgt die Fehlermeldung Er252 (a) bzw. Er253 (e). Die Betriebsart des starttec (C0014) muß unbedingt auf ”Mehrmotorenbetrieb” C0014 = 0 eingestellt werden.
  • Page 23: Leistungsanschlüsse - Drehrichtungsumkehr

    Show/Hide Bookmarks Elektrische Installation Leistungsanschlüsse - Drehrichtungsumkehr Stop! Schließen Sie die Netzzuleitung phasenrichtig an. Wenn die Netzphasen an den Anschlußklemmen vertauscht sind, erfolgt die Fehlermeldung Er252 (a) bzw. Er253 (e). Die Betriebsart des starttec (C0014) muß unbedingt auf ”Drehrichtungsumkehr” C0014 = 1 eingestellt werden. Der stattec wird sonst zerstört! 3/PE AC 100 V ...
  • Page 24: Anschluß Federkraftbremse

    Show/Hide Bookmarks Elektrische Installation Anschluß Federkraftbremse Gefahr! Auch bei gesperrtem starttec (X3/28 = LOW) führen die Anschlüsse 1V, 2V, B1 und B2 gefährliche Spannung. Spannungsfreiheit ist nur durch Abschalten der Netzspannung zu erreichen. Netz: 3/PE AC 230 V Netz: 3/N/PE AC 400 V starttec mit 205 VDC-Bremsspannung starttec mit 205 VDC-Bremsspannung 3/N/PE AC 400 V...
  • Page 25: Steueranschlüsse

    AS-interface (in Vorbereitung) † Externe Spannungsversorgung für die Steuerung des starttec Signaltyp Funktion Pegel Daten (fett = Lenze-Einstellung) Digitale LOW (0 V ... +3 V) starttec freigeben/sperren HIGH = starttec freigegeben Eingänge HIGH (+12 V ... +30 V) HIGH (+12 V ... +30 V)
  • Page 26: Starttec Zusammenbauen

    Show/Hide Bookmarks starttec zusammenbauen 2.4 Nm 21 lb-in start019 EDK71MMXXX-020 DE/EN/FR 1.0...
  • Page 27: Inbetriebnahme

    Show/Hide Bookmarks Inbetriebnahme Parametrieren mit dem Keypad Das Keypad E82ZBB ist als Zubehör erhältlich. Die vollständige Beschreibung des Keypad finden Sie im Faltblatt, das jedem Keypad beiliegt. Funktionstasten Statusanzeigen Bargraph-Anzeige Funktionsleiste 1 Funktionsleiste 2 Parametersatz Änderung Änderung Codenummer möglich, möglich, wenn An- Subcodenummer zeige blinkt...
  • Page 28 Show/Hide Bookmarks Inbetriebnahme Parametrieren mit dem Keypad Wechsel zwischenden Menüs U U U U S S S S E E E E r r r r und A A A A L L L L L L L L USEr Œ...
  • Page 29 Tip! Über C0002 ”Parametersatz-Transfer/Lieferzustand herstellen” können Sie bequem Konfi- gurationen von Antriebsregler zu Antriebsregler transferieren oder wieder den Lieferzu- stand herstellen, indem Sie die Lenze-Einstellung laden (z. B. wenn Sie beim Parametrieren ’den roten Faden’ verloren haben). EDK71MMXXX-020 DE/EN/FR 1.0...
  • Page 30 Show/Hide Bookmarks Inbetriebnahme Parametrieren mit dem Keypad Parameter in den Menüs ändern Schritt Tasten- Display Bemerkung Beispiel folge starttec Nur notwendig, wenn Sie Codes ändern wol- sperren len, die in der Codetabelle mit gekenn- zeichnet sind, z. B.: C0002 Alle anderen Parameter können Sie während des Betriebs ändern.
  • Page 31: Vor Dem Ersten Einschalten

    Die Betriebsart des starttec (C0014) muß unbedingt an die Verdrahtung angepaßt sein. Der starttec kann sonst zerstört werden: – Zwei Motoren, eine Drehrichtung: C0014 = 0 (Lenze-Einstellung) – Ein Motor, Drehrichtungswechsel: C0014 = 1! ... vor dem Freigeben des starttec die Einstellung der wichtigsten Antriebsparameter: Sind die für Ihre Anwendung relevanten Antriebsparameter richtig eingestellt?
  • Page 32: Mehrmotorenbetrieb - Ohne Keypad

    Wir empfehlen deshalb, auch die Betriebsart ”Mehrmotorenbetrieb” mit dem Keypad in Be- trieb zu nehmen, da Sie damit jeden Motor individuell einstellen können. In der Lenze-Einstellung (C0006 = -0-) können Sie die Hochlaufzeit (C0012), die Startspan- nung (C0016) und den Nennstrom (C0120) nur über Potentiometer bzw. Schalter parametrieren.
  • Page 33 Sie eine Feineinstellung in C0120 vornehmen start011 Stellen Sie die Hochlaufzeit t CINH starttec freigeben über X3/28 Poti [P2] ein Poti [P2] ein Lenze-Einstellung: 0 s Motor 1 starten CINH CINH CINH CINH CINH CINH CINH Verlauf der Spannung an Motor 1 3.00 s...
  • Page 34: Mehrmotorenbetrieb - Mit Keypad

    Wählen Sie die Betriebsart ”Mehr- C0014 = 0 muß eingestellt  motorenbetrieb aus (C0014 = 0) j g f k i h PS sein, um sicheren Mehr- 001 4 Lenze-Einstellung: C0014 = 0 motorenbetrieb zu ge- währleisten start231 EDK71MMXXX-020 DE/EN/FR 1.0...
  • Page 35 (C0012/1 Motor 1) Motor 1 starten (C0012/2 = Motor 2) Verlauf der Spannung an Lenze-Einstellung: 0.50 s Lenze Einstellung: 0.50 s Motor 1 Motor 2 starten Verlauf der Spannung an Motor 2 10. Stellen Sie die Ablaufzeit t für je-...
  • Page 36 Show/Hide Bookmarks Inbetriebnahme Mehrmotorenbetrieb - mit Keypad Einschaltreihenfolge Bemerkung 15. Einstellen Ein-/ Ausschaltverzöge- CINH starttec freigeben über CINH CINH CINH CINH CINH CINH CINH CINH CINH X3/28 rung der Bremse: rung der Bremse: Einschaltverzögerung t Einschaltverzögerung t (C0423) (C0423) Motor 1 starten Ausschaltverzögerung t (C0424) Boff...
  • Page 37: Ein Motor Mit Drehrichtungswechsel

    Werte Übernommen. Wählen Sie die Betriebsart ”Dreh- C0014 = 1 muß eingestellt  richtungswechsel” aus (C0014 = 1) j g f k i h PS sein, der starttec wird 001 4 Lenze-Einstellung: C0014 = 0 sonst zerstört! start232 EDK71MMXXX-020 DE/EN/FR 1.0...
  • Page 38 CINH CINH CINH CINH X3/28 (C0012/1) (C0012/1) Lenze-Einstellung: 0.50 s Lenze Einstellung: 0.50 s Motor starten Drehrichtung umkehren Verlauf der Spannung an 1U, 1V, 1W Verlauf der Spannung an 2U, 2V, 2W 10. Stellen Sie die Ablaufzeit t 10. Stellen Sie die Ablaufzeit t...
  • Page 39 Show/Hide Bookmarks Inbetriebnahme Ein Motor mit Drehrichtungswechsel Einschaltreihenfolge Bemerkung 15. Einstellen Ein-/ Ausschaltverzöge- CINH starttec freigeben über CINH CINH CINH CINH CINH CINH CINH CINH CINH X3/28 rung der Bremse: rung der Bremse: Einschaltverzögerung t Einschaltverzögerung t (C0423) (C0423) Motor starten Ausschaltverzögerung t (C0424) Boff...
  • Page 40: Codetabelle

    U U U U S S S S E E E E r r r r ist nach jedem Netzeinschalten aktiv. Bezeichnung Bezeichnung des Code Lenze Lenze-Einstellung (Wert bei Auslieferung oder nach Überschreiben mit der Lenze-Einstellung über C0002) Die Spalte ”WICHTIG” enthält weitere Information à Auswahl 99 min.
  • Page 41 Show/Hide Bookmarks Inbetriebnahme Codetabelle Code Einstellmöglichkeiten WICHTIG WICHTIG Bezeichnung Lenze Auswahl PAR1 C0002 Parametersatz- Bereit verwaltung Parametersatz des starttec U U U U S S S S E E E E r r r r PAR1 enthält auch die Para- meter für die...
  • Page 42 Show/Hide Bookmarks Inbetriebnahme Codetabelle Code Einstellmöglichkeiten WICHTIG WICHTIG Bezeichnung Lenze Auswahl PAR1 eigene Grundeinstellung Sie können für die C0002 Eigene Grund- ð Parameter des einstellung spei- starttec eine eigene U U U U S S S S E E E E r r r r...
  • Page 43 Show/Hide Bookmarks Inbetriebnahme Codetabelle Code Einstellmöglichkeiten WICHTIG WICHTIG Bezeichnung Lenze Auswahl C0006 Umschaltung Bei Umschal- C0012 C0016 C0120 HW/Keypad HW/Keypad tung von Key- tung von Key- U U U U S S S S E E E E r r r r HW wer- ð...
  • Page 44 Show/Hide Bookmarks Inbetriebnahme Codetabelle Code Einstellmöglichkeiten WICHTIG WICHTIG Bezeichnung Lenze Auswahl C0054 Motorschein- 50 Nur Anzeige strom Motor 1 U U U U S S S S E E E E r r r r C0055 Motorschein- 50 Nur Anzeige strom Motor 2 C0061 Gehäusetempe-...
  • Page 45 Show/Hide Bookmarks Inbetriebnahme Codetabelle Code Einstellmöglichkeiten WICHTIG WICHTIG Bezeichnung Lenze Auswahl C0150 starttec-Status- C0150 starttec Status Statusabfrage Statusabfrage Belegung wort 1 des starttec t tt Abbildung von C0417/1 (Parameterkanal) (Parameterkanal) über Parameter- über Parameter- Abbildung von C0417/2 kanal. Die wich- kanal.
  • Page 46 Nur Anzeige stunden C0200 Software-EKZ Nur Anzeige am PC C0201 Software-Erstel- Nur Anzeige am PC lungsdatum C0304 ... Service-Codes Veränderungen nur durch Lenze- C0309 Service! C0350 Systembus-Kno- 63 Änderung wird tenadresse nach Reset Node wirksam C0351 Systembus-Bau- C035 Syste bus au Änderung wird...
  • Page 47 Show/Hide Bookmarks Inbetriebnahme Codetabelle Code Einstellmöglichkeiten WICHTIG WICHTIG Bezeichnung Lenze Auswahl C0353 Quelle System- Quelle der Adresse C0350 ist Quelle bus-Adresse bus-Adresse für Systembus Pro- für Systembus Pro- C0354 ist Quelle zeßdatenkanäle 1 CAN1 (Sync) Wirksam bei Sync- Steuerung (C0360 = -1-)
  • Page 48 Show/Hide Bookmarks Inbetriebnahme Codetabelle Code Einstellmöglichkeiten WICHTIG WICHTIG Bezeichnung Lenze Auswahl C0356 Systembus Zeit- {1 ms} 65000 einstellungen 1 boot up 3000 Notwendig für CAN- Verbund ohne Ma- ster 2 Zykluszeit CAN- 0 und C0360 = 0: OUT2 ereignisgesteuerte Prozeßdatenüber- gabe >...
  • Page 49 Show/Hide Bookmarks Inbetriebnahme Codetabelle Code Einstellmöglichkeiten WICHTIG WICHTIG Bezeichnung Lenze Auswahl C0372 Identifizierung C0372 Identifizierung Nur Anzeige Nur Anzeige Kein Funktionsmodul F kti Funktionsmodul Systembus (CAN) LECOM-B (RS485), INTERBUS oder PRO- FIBUS -10- Keine gültige Erkennung 20.00 LOW/HIGH-Flanke C0408 Tipp-Betrieb digi- 0.00...
  • Page 50 Show/Hide Bookmarks Inbetriebnahme Codetabelle Code Einstellmöglichkeiten WICHTIG WICHTIG Bezeichnung Lenze Auswahl C0410 Freie Konfigura- tion digitale Ein- gangssignale (Forts.) 13 ... 16 reserviert -255- -90 ... -105- CAN-IN2.W2 Bit 0 (90) ... Bit 15 (105) -255- -200- Bitweise Zuordnung über FIF- 17 DCTRL1-H/Re Steuerwörter (FIF-CTRL1, FIF-...
  • Page 51 Show/Hide Bookmarks Inbetriebnahme Codetabelle Code Einstellmöglichkeiten WICHTIG WICHTIG Bezeichnung Lenze Auswahl C0415 Freie Konfigura- Keilriemenüberwa- -20- Motorscheinstrom Motor 1 < tion digitale Aus- chung Stromschwelle gänge (Forts.) (Forts.) (DCTRL1-IMOT<ILIM) Motorschein- Motorschein strom = C0054 C0054 -21- Motorscheinstrom Motor 2 <...
  • Page 52 Show/Hide Bookmarks Inbetriebnahme Codetabelle Code Einstellmöglichkeiten WICHTIG WICHTIG Bezeichnung Lenze Auswahl Die Zuordnung C0417 Freie Konfigura- Ausgabe digitaler Signale auf Bus tion starttec-Sta- wird abgebildet tus (1) auf das – starttec-Sta- – starttec-Sta- 1 Bit 0 Digitale Signalquellen wie C0415...
  • Page 53 Motorscheinstron wünschten Co- ü 9 Speicher 9 -121- C0003 Parameter nichtflüchtig spei- des eintragen chern 10 Speicher 10 C0002 Parametersatz-Transfer Veränderungen e ä de u ge C0518 Service-Code nur durch Lenze- C0519 Service-Code Service! Service! C0520 Service-Code EDK71MMXXX-020 DE/EN/FR 1.0...
  • Page 54: Störungen Erkennen Und Beseitigen

    Show/Hide Bookmarks Störungen erkennen und beseitigen Störungsmeldungen LED’s am starttec (Betriebszustandsanzeigen)7. Betriebszustand grün starttec freigegeben blinkt starttec gesperrt blinkt im 1-Sekunden-Takt Störung aktiv, Kontrolle in C0161 Störungsmeldungen am Keypad oder im Parametrierprogramm Global Drive Control Tip! Wenn der Code C0171 = 0.0 s eingestellt ist, müssen Sie eine TRIP-Störungsmeldung mit einer LOW/HIGH-Flanke an X3/28 (CINH) quittieren.
  • Page 55 Show/Hide Bookmarks Störungen erkennen und beseitigen Störungsmeldungen Anzeige Störung Ursache Abhilfe Keypad PC PTC-Überwachung O O O O H H H H 3 3 3 3 Motor zu warm durch unzulässig Antriebsauslegung prüfen (TRIP) hohe Ströme oder häufige und (wird nur generiert, zu lange Beschleunigungsvor- gänge wenn C0119 = 1)
  • Page 56 = Stand-alone drive x2x = Multi-motor operation, change of direction of rotation Hardware version Software version Read the Mounting Instructions before you start working! Please observe all safety information given. ã 2001 Lenze GmbH & Co KG Stand 1.0 09/2001 TD00...
  • Page 57 Show/Hide Bookmarks start209 ¶ 21 Motor 1 connection [1U], [1V], [1W], [PE] [2U], [2V], [2W], [PE] Motor 2 connection [L1], [L2], [L3], [PE] Mains connection ¶ 21 ¶ 23 [B1], [B2], [BN] Connection of spring-operated brake ¶ 24 Control connection Step switch for setting the rated motor current ¶...
  • Page 58 Set the rated current according to the connected motor by using the [S] or via C0120. The startec control mode (C0014) must be adapted to the wiring. Otherwise, the starttec can be damaged: Two motors, one direction of rotation: C0014 = 0 (Lenze setting) One motor, change of direction of rotation: C0014 = 1!
  • Page 59 ..........Lenze low-voltage machinery .
  • Page 60: Safety Instructions

    (according to Low-Voltage Directive 73/23/EEC) 1. General Some parts of Lenze motor starters can be live, moving and rotating, depending on their protection class. Surfaces can be hot. Non-authorized removal of the required cover, inappropriate use, incorrect installation or operation, creates the risk of severe injury to persons or damage to material assets.
  • Page 61 Show/Hide Bookmarks Safety instructions Motor starter 5. Electrical connection When working on live motor starters, the applicable national regulations for the prevention of accidents (e.g. VBG 4) must be observed. The electrical installation must be carried out according to the appropriate regulations (e.g. cable cross-sections, fuses, PE connection).
  • Page 62: Lenze Low-Voltage Machinery

    Show/Hide Bookmarks Safety instructions Lenze low-voltage machinery General safety and and application notes for Lenze low-voltage machinery (in conformity with the Low-Voltage Directive 73/23/EEC) 1. General Low-voltage machines have dangerous, live and rotating parts as well as possibly hot surfaces. All operations serving transport, connection, commissioning and maintenance are to be carried out by skilled, responsible technical personnel (observe EN 50110-1 (VDE 0105-100);...
  • Page 63 Show/Hide Bookmarks Safety instructions Lenze low-voltage machinery 5. Electrical connection All operations must be carried out only by qualified and skilled personnel when the low-voltage machine is at standstill and when the machine is de-energized and protected against unintentional restart. This also applies to auxiliary circuits (e.g.
  • Page 64: Residual Hazards, Layout Of Safety Instructions

    Show/Hide Bookmarks Safety instructions Residual hazards, layout of safety instructions Residual hazards Protection of Disconnect the starttec before you start working on the device or opening it because the persons power connections L1, L2, L3, 1U, 1V, 1W, 2U, 2V, 2W, B1, B2 and BN carry dangerous voltage: –...
  • Page 65: Technical Data

    Show/Hide Bookmarks Technical data General data Conformity Low-Voltage Directive (73/23/EEC) EMC Directive (93/68/EEC) Standards DIN EN 60947-4-2 Semiconductor motor control devices and starters for AC voltage Approvals UL 508 Underwriter Laboratories (File-No. E132659) Power Conversion Equipment (in preparation) Vibration resistance Acceleration resistant up to 4g (Germanischer Lloyd, general conditions) Climatic conditions Class 3K3 to EN 50178 (without condensation, average relative humidity 85...
  • Page 66: Rated Data

    Show/Hide Bookmarks Technical data Rated data Rated data - motor switch/brake switch 100 V 0 % ≤ Vr ≤ 550 V +0 %; 45 Hz ... 65 Hz ±0 % Mains voltage Max. output current 9.5 A Motor power mains voltage 3 230 V P 0.25 ...
  • Page 67 Show/Hide Bookmarks Technical data Rated data Thermal monitoring According to DIN EN 60947-4-2 (semiconductor motor control devices and starters for AC voltage) ... the starttec will switch off If the motor current is x-times ... with an activation higher than the o tp t c rrent higher than the output current class set nder C0121 class set under C0121...
  • Page 68 Show/Hide Bookmarks Technical data Rated data Rated control data Features Terminal Specification DC supply of control X3/59 Voltage +18 VDC ... +30 VDC Current consumption 200 mA at 24 V (without load connected to X3/20) Internal DC supply X3/20 +18 VDC ... +30 VDC, max. 500 mA Digital inputs X3/28 HIGH active...
  • Page 69: Dimensions, Mechanical Design

    Show/Hide Bookmarks Technical data Dimensions, mechanical design Dimensions start001 a [mm] b [mm] c [mm] d [mm] e [mm] 228.0 10.0 104.5 129.0 71.0 Mechanical design Housing Cable connections Weight Housing with electronic module from 4 M20 (threaded length 10 mm) aluminium die-cast 1.3 kg 6 M16 (threaded length 10 mm)
  • Page 70: Motor Mounting

    Show/Hide Bookmarks Motor mounting Delivery package Abb. 1-9 start010 Housing with electronic module Housing cover Distance and wall mounting plate Seal Screws KA 50 x 18 for wall mounting EDK71MMXXX-020 DE/EN/FR 1.0...
  • Page 71: Preparation

    Show/Hide Bookmarks Motor mounting Preparation 3.4 Nm 30 lb-in 68-73mm Abb. 1-10 4 × 6 × start024 Screw (DIN 7985) 20 mm Serrated lock washer to DIN 6798 EDK71MMXXX-020 DE/EN/FR 1.0...
  • Page 72: Wall Mounting

    Show/Hide Bookmarks Wall mounting Delivery package Abb. 1-11 start010 Housing with electronic module Housing cover Distance and wall mounting plate Seal Screws KA 50 x 18 for wall mounting EDK71MMXXX-020 DE/EN/FR 1.0...
  • Page 73: Preparation

    Show/Hide Bookmarks Wall mounting Preparation 5.3 mm 4 × 6 × Abb. 1-12 3.4 Nm 30 lb-in start022 Distance and wall mounting plate Drilling pattern Distance a [mm] b [mm] c [mm] d [mm] e [mm] EDK71MMXXX-020 DE/EN/FR 1.0...
  • Page 74: Electrical Installation

    The startec control mode (C0014) must be adapted to the wiring. Otherwise, the starttec can be damaged: – Two motors, one direction of rotation: C0014 = 0 (Lenze setting) – One motor, change of direction of rotation: C0014 = 1! Fuses and cable cross-sections Cable cross-sections and fuses (slow) must be selected according to the max.
  • Page 75: Power Connections - Two Motors

    Show/Hide Bookmarks Electrical installation Power connections - Two motors Stop! Connect the mains cable in phase. If the mains phases are mixed up, the following error message will appear: Er252 ( a) or Er253 ( e). The starttec control mode (C0014) must be set for ”Multi-motor operation” C0014 = 0.
  • Page 76: Power Connections - Change Of Direction Of Rotation

    Show/Hide Bookmarks Electrical installation Power connections - Change of direction of rotation Stop! Connect the mains cable in phase. If the mains phases are mixed up, the following error message will appear: Er252 (a) or Er253 (e). The starttec control mode (C0014) must be set for ”Change of direction of rotation” C0014 = 1.
  • Page 77: Spring-Operated Brake

    Show/Hide Bookmarks Electrical installation Spring-operated brake Danger! Even if the starttec is inhibited (X3/28 = LOW), the connections 1V, 2V, B1 and B2 carry dangerous voltage! Only complete disconnection from the mains supply can ensure that the device is free of voltage. Mains: 3/PE AC 230 V Mains: 3/N/PE AC 400 V starttec with 205 VDC brake voltage...
  • Page 78: Control Connections

    † External voltage supply for controlling the starttec Signal Function Level Data type (bold = Lenze setting) Digital LOW (0 V ... +3 V) starttec enable/inhibit HIGH = starttec enabled inputs HIGH (+12 V ... +30 V) HIGH (+12 V ... +30 V) LOW = starttec inhibited Input current: max.
  • Page 79: Starttec Assembly

    Show/Hide Bookmarks starttec assembly 2.4 Nm 21 lb-in start019 EDK71MMXXX-020 DE/EN/FR 1.0...
  • Page 80: Commissioning

    (example: C0517 menu User). The menu User – is active after every mains switching or keypad attachment during operation. – contains all codes required for a standard application (Lenze setting). – can be modified as required under C0517. The menu all –...
  • Page 81 Show/Hide Bookmarks Commissioning Parameter setting using the keypad Change between menus U U U U S S S S E E E E r r r r and A A A A L L L L L L L L USEr Œ...
  • Page 82 C0002 Parameter set transfer/reset See code table ( ¶ 38) Note! Use C0002 ”Parameter set transfer” to easily transfer configurations from one controller to the other or to reset the controller to Lenze settings. Parameter change in menus Step Keys...
  • Page 83: Before Switching On

    The startec control mode (C0014) must be adapted to the wiring. Otherwise, the starttec can be damaged: – Two motors, one direction of rotation: C0014 = 0 (Lenze setting) – One motor, change of direction of rotation: C0014 = 1! ...
  • Page 84: Multi-Motor Operation - Without Keypad

    We therefore recommend to use the keypad for ”multi-motor operation” because it is then possible to individually set every motor. With Lenze setting (C0006 = -0-), acceleration time (C0012), start voltage (C0016) and rated current (C0120) can only be set via potentiometer or switch.
  • Page 85 C0120 for fine adjustment start011 Set the acceleration time t with the CINH Enable starttec via X3/28 potentiometer [P2] potentiometer [P2] Motor 1 start Lenze setting: 0 s CINH CINH CINH CINH CINH CINH CINH Motor 1 voltage flow Brake control 3.00 s...
  • Page 86: Multi-Motor Operation - With Keypad

    P1, P2 and S. Select the control mode C0014 = 0 must be set to ”Multi-motor operation”  j g f k i h PS ensure safe multi-motor 001 4 (C0014 = 0) operation Lenze setting: C0014 = 0 start231 EDK71MMXXX-020 DE/EN/FR 1.0...
  • Page 87 Motor 1 start (C0012/1 = Motor 1) (C0012/1 = Motor 1) (C0012/2 = Motor 2) Motor 1 voltage flow Lenze setting: 0 50 s Lenze setting: 0.50 s Motor 2 start Motor 2 voltage flow 10. Set the deceleration time t...
  • Page 88 Show/Hide Bookmarks Commissioning Multi-motor operation - with keypad Switch-on sequence Note 15. Setting of the brake switch on/off 15. Setting of the brake switch on/off CINH CINH CINH CINH CINH CINH CINH CINH CINH CINH delay: Motor 1 start S it h Switch on delay t (C0423) (C0423)
  • Page 89: One Motor - Change Of Direction Of Rotation

    (C0014 = 1)  j g f k i h PS otherwise the starttec will 001 4 Lenze setting: C0014 = 0 be damaged! start232 Set the acceleration time t Set t e acce e at o t e t...
  • Page 90 If C0016 = 100 %, the start acceleration time t (C0012) (C0016/1) 100% is not active Lenze setting: 40.0 % start start028 12. Set the rated motor current C0120 = 0.0: I t switch off  j g f k i h PS...
  • Page 91: Code Table

    U U U U S S S S E E E E r r r r is active after every mains switching. Name Name of the code Lenze Lenze setting (value set at delivery or after overwriting of C0002 with Lenze setting) à Further information can be obtained from ”IMPORTANT” Selection 99 Min.
  • Page 92 FPAR1: Module-specific parameter set of PROFIBUS-DP, INTERBUS, DeviceNet/ CANopen or LECOM-B FPAR1 is saved in the function module Restorage of Lenze setting PAR1 Restorage in ð default setting parameter set -31- Lenze setting FPAR1 Restorage of ð default setting in...
  • Page 93 Show/Hide Bookmarks Commissioning Code table Code Possible settings IMPORTANT IMPORTANT Name Lenze Selection PAR1 Own settings You can save your C0002 Store your own ð own basic settings basic settings for starttec U U U U S S S S E E E E r r r r parameters (e.
  • Page 94 Show/Hide Bookmarks Commissioning Code table Code Possible settings IMPORTANT IMPORTANT Name Lenze Selection C0006 Changeover Keypad C0012 C0016 C0120 between HW and between HW and changeover changeover ð ð keypad U U U U S S S S E E E E r r r r...
  • Page 95 Show/Hide Bookmarks Commissioning Code table Code Possible settings IMPORTANT IMPORTANT Name Lenze Selection C0043 TRIP reset No current error Reset active error with C0043 = 0 Active fault C0054 Apparant motor 1 50 Only display current U U U U S S S S E E E E r r r r...
  • Page 96 Show/Hide Bookmarks Commissioning Code table Code Possible settings IMPORTANT IMPORTANT Name Lenze Selection C0150 starttec status C0150 starttec status starttec status starttec status Assignment word 1 via parameter Mapping of C0417/1 (Parameter (Parameter channel The channel. The Mapping of C0417/2...
  • Page 97 C0201 Software Only PC display generation date Modifications only C0304 ... Service codes C0309 by Lenze Service! C0350 System bus node 63 Change will only be address effective after reset node C0351 System bus baud C035 Syste bus baud...
  • Page 98 Show/Hide Bookmarks Commissioning Code table Code Possible settings IMPORTANT IMPORTANT Name Lenze Selection C0353 System bus Address source for C0350 is source address source address source system bus process system bus process C0354 is the source data channels 1 CAN1 (sync)
  • Page 99 Show/Hide Bookmarks Commissioning Code table Code Possible settings IMPORTANT IMPORTANT Name Lenze Selection C0356 System bus time {1 ms} 65000 settings 1 Boot up 3000 Required for CAN network without master 2 Cycle time 0 and C0360 = 0: CAN-OUT2...
  • Page 100 Show/Hide Bookmarks Commissioning Code table Code Possible settings IMPORTANT IMPORTANT Name Lenze Selection C0372 Function module C0372 Function module Only display Only display No function module id tifi ti identification System bus (CAN) LECOM-B (RS485), INTERBUS or PROFIBUS -10- No valid recognition 20.00 LOW/HIGH edge at...
  • Page 101 Show/Hide Bookmarks Commissioning Code table Code Possible settings IMPORTANT IMPORTANT Name Lenze Selection C0410 Free configuration of digital input (cont.) signals 13 ... 16 Reserved -255- -90 ... -105- CAN-IN2.W2 Bit 0 (90) ... bit 15 (105) -255- -200- Bit-by-bit assignment of the FIF...
  • Page 102 Show/Hide Bookmarks Commissioning Code table Code Possible settings IMPORTANT IMPORTANT Name Lenze Selection C0415 Free Belt monitoring -20- Apparent motor 1 current < configuration of current threshold Apparent motor digital outputs (cont.) (cont.) (DCTRL1-IMOT<ILIM) current = C0054 current C0054 Current threshold = -21- Apparent motor 2 current <...
  • Page 103 Show/Hide Bookmarks Commissioning Code table Code Possible settings IMPORTANT IMPORTANT Name Lenze Selection The assignment C0417 Free Output of digital signals to bus configuration of is mapped to starttec status (1) – starttec statzs – starttec statzs 1 Bit 0...
  • Page 104 Show/Hide Bookmarks Commissioning Code table Code Possible settings IMPORTANT IMPORTANT Name Lenze Selection The assignment C0418 Free Output of digital signals to bus configuration of is mapped to starttec status (2) – starttec status word 2 (C0151) (C0151) 1 Bit 0 Digital signal sources like C0415 –...
  • Page 105 Apparent motor current numbers in the 9 Memory 9 -121- C0003 Non-volatile parameter saving subcodes subcodes. 10 Memory 10 C0002 Parameter set transfer Modifications only Modifications only C0518 Service code by Lenze Service! C0519 Service code C0520 Service code EDK71MMXXX-020 DE/EN/FR 1.0...
  • Page 106: Troubleshooting

    Show/Hide Bookmarks Troubleshooting Error messages LEDs at starttec (operating status display)7. Operating status green starttec enabled blinking starttec inhibit blinking every second Fault active, check under C0161 Error messages at the keypad or in the parameter setting program Global Drive Control Note! If code C0171 = 0.0 s is set, TRIP error messages must be acknowledged with a LOW/HIGH transition at X3/28 (CINH).
  • Page 107 Show/Hide Bookmarks Troubleshooting Error messages Display Fault Cause Remedy Keypad PC PTC monitoring O O O O H H H H 3 3 3 3 Motor too hot because of Check drive selection (TRIP) impermissibly high currents or (only generated if frequent excessively long acceleration processes C0119 = 1)
  • Page 108 = Fonctionnement multimoteurs, inversion du sens de rotation Version du matériel Version du logiciel Respecter les consignes de sécurité. Lire attentivement les instructions de montage avant toute opération ! ã 2001 Lenze GmbH & Co KG Stand 1.0 09/2001 TD00...
  • Page 109 Show/Hide Bookmarks start209 ¶ 21 Raccordement moteur 1 [1U], [1V], [1W], [PE] [2U], [2V], [2W], [PE] Raccordement moteur 2 [L1], [L2], [L3], [PE] Raccordement réseau ¶ 21 ¶ 23 [B1], [B2], [BN] Raccordement frein à ressorts à manque de courant ¶...
  • Page 110 Le mode de fonctionnement du starttec (C0014) doit être impérativement adapté au câblage. Autrement, le starttec risque d’être détruit. Deux moteurs avec le même sens de rotation : C0014 = 0 (réglage Lenze) Un moteur avec inversion du sens de rotation : C0014 = 1 !
  • Page 111 ........Démarreurs moteur Lenze .
  • Page 112: Consignes De Sécurité

    Conformes à la directive Basse Tension 73/23/CEE 1. Généralités Selon leur degré de protection, les démarreurs moteur Lenze peuvent avoir, pendant leur fonctionnement, des parties sous tension, éventuellement en mouvement ou tournantes. Les surfaces risquent d’être chaudes. Un enlèvement non autorisé des protections prescrites, un usage non conforme à la fonction, une installation défectueuse ou une manoeuvre erronée peuvent entraîner des dommages corporels et matériels graves.
  • Page 113 Show/Hide Bookmarks Consignes de sécurité Démarreurs moteur Lenze 5. Raccordement électrique Lorsque des travaux sont effectués sur le démarreur moteur sous tension, les prescriptions nationales pour la prévention d’accidents doivent être respectées (par exemple VBG 4). L’installation électrique doit être exécutée en conformité avec les prescriptions applicables (par exemple sections des conducteurs, protection par coupe-circuit à...
  • Page 114: Machines À Courant Triphasé

    Show/Hide Bookmarks Consignes de sécurité Machines à courant triphasé Instructions de sécurité et de mise en service relatives aux machines à basse tension Conformes à la directive Basse Tension 73/23/CEE 1. Généralités Les machines à basse tension comportent des parties dangereuses sous tension et tournantes, ainsi que, le cas échéant, des surfaces chaudes.
  • Page 115 Show/Hide Bookmarks Consignes de sécurité Machines à courant triphasé 5. Raccordement électrique Les travaux ne doivent être effectués que par du personnel qualifié habilité, la machine étant au repos, séparée de l’alimentation et protégée contre tout réenclenchement intempestif. Ceci vaut également pour les circuits auxiliaires (exemples : frein, codeur, motoventilateur).
  • Page 116: Dangers Résiduels, Présentation Des Consignes De Sécurité

    Show/Hide Bookmarks Consignes de sécurité Dangers résiduels, présentation des consignes de sécurité Dangers résiduels Protection Les bornes de puissance L1, L2, L3, 1U, 1V, 1W, 2U, 2V, 2W, B1, B2 et BN étant sous tension, couper le starttec du réseau avant d’ouvrir l’appareil ou de procéder aux travaux personnes sur le starttec.
  • Page 117: Spécifications Techniques

    Show/Hide Bookmarks Spécifications techniques Caractéristiques générales Conformité Directive Basse Tension (73/23/CEE) Directive CEM (93/68/CEE) Normes DIN EN 60947-4-2 Gradateurs et démarreurs à semiconducteurs de moteurs à courant alternatif Homologations UL 508 Underwriter Laboratories (File-No. E132659) Power Conversion Equipment (en préparation) Résistance aux chocs Résistance à...
  • Page 118: Caractéristiques Nominales

    Show/Hide Bookmarks Spécifications techniques Caractéristiques nominales Caractéristiques nominal démarreur moteur/commutateur frein 100 V 0 % ≤ UN ≤ 550 V +0 % ; 45 Hz ... 65 Hz ±0 % Tension d’alimentation réseau Tension de sortie maxi 9,5 A réseau Puissance moteur Pour tension d’alimentation 3 230 V P 0,25 ...
  • Page 119 Show/Hide Bookmarks Spécifications techniques Caractéristiques nominales Surveillance thermique Selon DIN EN 60947-4-2 (gradateurs et démarreurs à semiconducteurs de moteurs à courant alternatif) Avec les multiples suivantes Avec les multiples suivantes ... le starttec est désactivé ... avec une classe de ...
  • Page 120 Show/Hide Bookmarks Spécifications techniques Caractéristiques nominales Caractéristiques nominales - commande Caractéristique Borne Spécification Alimentation CC commande X3/59 Tension +18 VCC ... +30 VCC Courant absorbé 200 mA pour 24 V (sans récepteur sur X3/20) Alimentation CC interne X3/20 +18 VCC ... +30 VCC, 500 mA maxi Entrées numériques X3/28 Activé...
  • Page 121: Encombrements, Conception Mécanique

    Show/Hide Bookmarks Spécifications techniques Encombrements, conception mécanique Encombrements start001 a [mm] b [mm] c [mm] d [mm] e [mm] 228,0 10,0 104,5 129,0 71,0 Conception mécanique Boîtier Raccords vissés Poids Boîtier en aluminium coulé sous pression 4 x M20 (longueur filetée 10 mm) avec module électronique 1,3 kg 6 x M16 (longueur filetée 10 mm)
  • Page 122: Montage Sur Le Moteur

    Show/Hide Bookmarks Montage sur le moteur Equipement livré Abb. 1-17 start010 Boîtier avec module électronique Couvercle du boîtier Entretoise/plaque de montage Joint Vis KA 50 x 18 pour montage au mur/sur le bâti de la machine EDK71MMXXX-020 DE/EN/FR 1.0...
  • Page 123: Préparatifs

    Show/Hide Bookmarks Montage sur le moteur Préparatifs 3.4 Nm 30 lb-in 68-73mm Abb. 1-18 4 × 6 × start024 Vis (DIN 7985) 20 mm Rondelle à dents chevauchantes selon DIN 6798 EDK71MMXXX-020 DE/EN/FR 1.0...
  • Page 124: Montage Au Mur/Sur Le Bâti De La Machine

    Show/Hide Bookmarks Montage au mur/sur le bâti de la machine Equipement livré Abb. 1-19 start010 Boîtier avec module électronique Couvercle du boîtier Entretoise/plaque de montage Joint Vis KA 50 x 18 pour montage au mur/sur le bâti de la machine EDK71MMXXX-020 DE/EN/FR 1.0...
  • Page 125: Préparatifs

    Show/Hide Bookmarks Montage au mur/sur le bâti de la machine Préparatifs 5.3 mm 4 × 6 × Abb. 1-20 3.4 Nm 30 lb-in start022 Entretoise/plaque de montage Orifices de perçage Distance a [mm] b [mm] c [mm] d [mm] e [mm] EDK71MMXXX-020 DE/EN/FR 1.0...
  • Page 126: Installation Électrique

    Le mode de fonctionnement du starttec (C0014) doit être impérativement adapté au câblage. Autrement, le starttec risque d’être détruit. – Deux moteurs avec le même sens de rotation : C0014 = 0 (réglage Lenze) – Un moteur avec inversion du sens de rotation : C0014 = 1 ! Fusibles et sections de câbles...
  • Page 127: Partie Puissance - Deux Moteurs

    Show/Hide Bookmarks Installation électrique Partie puissance - deux moteurs Stop ! Assurer un raccordement en phase du câble réseau. Si les phases réseau sont inversées sur le bornier de raccordement, le message défaut suivant est affiché : Er252 (a) ou Er253 (e). Le mode de fonctionnement du starttec (C0014) doit être impérativement réglé...
  • Page 128: Partie Puissance - Inversion Du Sens De Rotation

    Show/Hide Bookmarks Installation électrique Partie puissance - inversion du sens de rotation Stop ! Assurer un raccordement en phase du câble réseau. Si les phases réseau sont inversées sur le bornier de raccordement, le message défaut suivant est affiché : Er252 ( a) ou Er253 ( e).
  • Page 129: Raccordement Frein À Ressorts À Manque De Courant

    Show/Hide Bookmarks Installation électrique Raccordement frein à ressorts à manque de courant Danger ! Même le starttec bloqué (borne 28 = BAS), les raccords 1V, 2V, B1 et B2 sont sous tension dangereuse. Pour obtenir une mise hors tension, il faut couper la tension réseau. Alimentation : 3/PE CA 230 V Alimentation : 3/N/PE CA 400 V starttec avec tension de freinage 205 VCC...
  • Page 130: Partie Commande

    † Alimentation externe pour la commande du starttec Type de Fonction Niveau Données signal (en gras = réglage Lenze) Entrées BAS (0 V ... +3 V) Déblocage/blocage du HAUT = starttec débloqué numériques starttec HAUT (+12 V ... +30 V) HAUT (+12 V ...
  • Page 131: Assemblage Du Starttec

    Show/Hide Bookmarks Assemblage du starttec 2.4 Nm 21 lb-in start019 EDK71MMXXX-020 DE/EN/FR 1.0...
  • Page 132: Mise En Service

    Show/Hide Bookmarks Mise en service Paramétrage à l’aide du clavier de commande Le clavier de commande E82ZBB est disponible en option. Pour la description complète du clavier de commande, se reporter à la feuille comprise dans l’emballage du clavier. Touches de fonction Affichages d’états Affichage graphique de barres Barre de fonction 1...
  • Page 133 Show/Hide Bookmarks Mise en service Paramétrage à l’aide du clavier de commande Comment passer du menu U U U U S S S S E E E E r r r r à A A A A L L L L L L L L USEr Œ...
  • Page 134 à la livraison en programmant le réglage Lenze (si, par exemple, pendant le paramétrage vous ne savez plus où vous en êtes et que vous souhaitez recommencer vos réglages).
  • Page 135 Show/Hide Bookmarks Mise en service Paramétrage à l’aide du clavier de commande Comment modifier les paramètres Etape Sé- Remarque Exemple quence fichage touches Bloquer le Uniquement nécessaire pour modifier les starttec. codes marqués par dans le tableau des codes. Exemple : C0002 Tous les autres paramètres peuvent être modifiés pendant le fonctionnement.
  • Page 136: Avant La Première Mise En Service

    Le mode de fonctionnement du starttec (C0014) doit être impérativement adapté au câblage. Autrement, le starttec risque d’être détruit. – Deux moteurs avec le même sens de rotation : C0014 = 0 (réglage Lenze) – Un moteur avec inversion du sens de rotation : C0014 = 1 ! ...
  • Page 137: Fonctionnement Multimoteurs-Sans Clavier De Commande

    Nous vous recommandons de procéder à une mise en service du mode de fonctionnement ”multimoteurs” via clavier afin de régler chaque moteur individuellement. Par le réglage Lenze (C0006 = -0-), le temps d’accélération (C0012), la tension de démarrage (C0016) et le courant nominal (C0120) ne peuvent être paramétrés que via potentiomètre ou gradateur.
  • Page 138 Régler le temps d’accélération t à CINH Débloquer le starttec via X3/28. l’aide du potentiomètre [P2]. l aide du potentiomètre [P2]. Réglage Lenze : 0 s Démarrer le moteur 1. CINH CINH CINH CINH CINH CINH CINH...
  • Page 139: Fonctionnement Multimoteurs-Avec Clavier De Commande

    Régler C0014 = 0 afin Sélectionner le mode de fonctionnement ”multimoteurs”  j g f k i h PS d’assurer la fonctionnalité 001 4 (C0014 = 0) du fonctionnement Réglage Lenze : C0014 = 0 multimoteurs. start231 EDK71MMXXX-020 DE/EN/FR 1.0...
  • Page 140 Démarrer le moteur 1. (C0012/2 (C0012/2 = moteur 2) moteur 2) Courbe de tension moteur 1 Réglage Lenze : 0 50 s Réglage Lenze : 0.50 s Démarrer le moteur 2. Courbe de tension moteur 2 10. Régler le temps de décélération t...
  • Page 141 Show/Hide Bookmarks Mise en service Fonctionnement multimoteurs-avec clavier de commande Ordre des opérations Remarque 15. Réglage temporisation CINH Débloquer le starttec via CINH CINH CINH CINH CINH CINH CINH CINH CINH X3/28. enclenchement/coupure du frein : enclenchement/coupure du frein : Temporisation d’enclenchement t Temporisation d enclenchement t Démarrer le moteur 1.
  • Page 142: Un Moteur Avec Inversion Du Sens De Rotation

    Sélectionner le mode de fonctionnement ”inversion du sens  j g f k i h PS C0014 = 1 sous risque de 001 4 de rotation” (C0014 = 1) détruire le starttec ! Réglage Lenze : C0014 = 0 start232 EDK71MMXXX-020 DE/EN/FR 1.0...
  • Page 143 CINH CINH CINH CINH CINH X3/28. (C0012/1). (C0012/1). Réglage Lenze : 0.50 s Réglage Lenze : 0.50 s Démarrer le moteur. Inversion du sens de rotation Courbe de tension sur 1U, 1V, 1W Courbe de tension sur 2U, 2V, 2W 10.
  • Page 144 Show/Hide Bookmarks Mise en service Un moteur avec inversion du sens de rotation Ordre des opérations Remarque 15. Réglage temporisation CINH Débloquer le starttec via CINH CINH CINH CINH CINH CINH CINH CINH CINH X3/28. enclenchement/coupure du frein : enclenchement/coupure du frein : Temporisation d’enclenchement Temporisation d enclenchement Démarrer le moteur.
  • Page 145: Tableau Des Codes

    . Le menu actif après chaque mise sous tension. Désignation Désignation du code Lenze Réglage Lenze (valeur disponible à la livraison ou après substitution par le réglage Lenze en C0002) La colonne ”IMPORTANT” contient des informations supplémentaires. à Choix 99 Valeur mini {unité}...
  • Page 146 Show/Hide Bookmarks Mise en service Tableau des codes Code Réglages possibles IMPORTANT IMPORTANT N° Désignation Lenze Choix Réglage Lenze PAR1 Retour au réglage Retour au ð usine (état à la réglage usine livraison) du jeu de (état à la livraison) paramètres -31- Réglage Lenze...
  • Page 147 Show/Hide Bookmarks Mise en service Tableau des codes Code Réglages possibles IMPORTANT IMPORTANT N° Désignation Lenze Choix PAR1 Votre propre réglage de base Il est possible de C0002 Sauvegarder ð sauvegarder votre votre propre propre réglage de U U U U S S S S E E E E r r r r réglage de base...
  • Page 148 Show/Hide Bookmarks Mise en service Tableau des codes Code Réglages possibles IMPORTANT IMPORTANT N° Désignation Lenze Choix C0006 Changement Lors de C0012 C0016 C0120 paramétrage via changement de matériel/via matériel/via U U U U S S S S E E E E U U U U S S S S E E E E r r r r paramétrage via...
  • Page 149 Mise en service Tableau des codes Code Réglages possibles IMPORTANT IMPORTANT N° Désignation Lenze Choix C0016 Tension de {0.1 %} 100.0 Tension de démarrage U démarrage moteur U U U U S S S S E E E E r r r r...
  • Page 150 Show/Hide Bookmarks Mise en service Tableau des codes Code Réglages possibles IMPORTANT IMPORTANT N° Désignation Lenze Choix 2 Courant nom. 2 Moteur 2 (uniquement en fonctionnement multimoteurs) Voir ¶ 13 C0121 Classe de C0121 Classe de Voir t désactivée dé l déclenchement...
  • Page 151 Show/Hide Bookmarks Mise en service Tableau des codes Code Réglages possibles IMPORTANT IMPORTANT N° Désignation Lenze Choix C0150 Mot d’état C0150 Mot d état Interrogation de Interrogation de Affectation starttec 1 t tt l’ét t t tt l’état starttec Représentation de C0417/1...
  • Page 152 C0200 N° Seulement en d’identification affichage PC du logiciel C0201 Date de création Seulement en du logiciel affichage PC Modifications C0304 ... Codes service Lenze uniquement par le C0309 service Lenze ! EDK71MMXXX-020 DE/EN/FR 1.0...
  • Page 153 Show/Hide Bookmarks Mise en service Tableau des codes Code Réglages possibles IMPORTANT IMPORTANT N° Désignation Lenze Choix C0350 Adresse sur le 63 Modification prise bus CAN en compte après Reset Node (réarmement noeuds) C0351 Vitesse de C0351 Vitesse de Modification prise...
  • Page 154 Show/Hide Bookmarks Mise en service Tableau des codes Code Réglages possibles IMPORTANT IMPORTANT N° Désignation Lenze Choix C0354 Adresse bus 513 Adressage système sélectif individuel des objets données process du bus système 1 CAN-IN1 (Sync) Activé avec commande Sync (C0360 = 1)
  • Page 155 Show/Hide Bookmarks Mise en service Tableau des codes Code Réglages possibles IMPORTANT IMPORTANT N° Désignation Lenze Choix C0356 Réglages des {1 ms} 65000 temps bus système 1 boot up 3000 Nécessaire pour le réseau d’anneau CAN sans maître 2 Temps de cycle...
  • Page 156 Show/Hide Bookmarks Mise en service Tableau des codes Code Réglages possibles IMPORTANT IMPORTANT N° Désignation Lenze Choix C0370 Activation Seulement en Désactivé réglage à réglage à affichage affichage -1- ... Adresse CAN correspondante activée distance -1- = Adresse -63- CAN 1 -63- = Adresse -255- Bus système (CAN) n’existe pas...
  • Page 157 Show/Hide Bookmarks Mise en service Tableau des codes Code Réglages possibles IMPORTANT IMPORTANT N° Désignation Lenze Choix C0410 Configuration Interconnexion de libre des signaux sources signaux d’entrées externes avec des numériques signaux numériques internes -0- ; -255- 0 ; 255 Non utilisé...
  • Page 158 Show/Hide Bookmarks Mise en service Tableau des codes Code Réglages possibles IMPORTANT IMPORTANT N° Désignation Lenze Choix C0415 C0415 Configuration Configuration Sortie de signaux Sortie de signaux -0- ; -255- Non utilisé (FIXED-FREE) libre sorties numériques sur é i -1- ; -2- Réservé...
  • Page 159 Show/Hide Bookmarks Mise en service Tableau des codes Code Réglages possibles IMPORTANT IMPORTANT N° Désignation Lenze Choix C0416 C0416 Inversion niveau Inversion niveau 0 : Sortie non 0 : Sortie non sorties inversée é numériques numériques (activée à l’état (activée à l’état...
  • Page 160 Show/Hide Bookmarks Mise en service Tableau des codes Code Réglages possibles IMPORTANT IMPORTANT N° Désignation Lenze Choix L’affectation est C0418 Configuration Sortie de signaux numériques sur bus libre état starttec représentée sur – le mot d’état starttec 2 (C0151) – le mot de 1 Bit 0 Sources signaux numériques comme C0415...
  • Page 161 Sauvegarder les paramètres en sous-codes. mémoire non volatile 10 Mémoire 10 C0002 Transfert de jeux de paramètres Modifications C0518 Code service uniquement par le uniquement par le Lenze service Lenze ! C0519 Code service Lenze C0520 Code service Lenze EDK71MMXXX-020 DE/EN/FR 1.0...
  • Page 162: Détection Et Élimination Des Défauts

    Show/Hide Bookmarks Détection et élimination des défauts Messages défauts LEDs sur le starttec (affichages d’états de fonctionnement) Etat de fonctionnement verte rouge ALLUMEE ETEINTE starttec débloqué CLIGNOTE ETEINTE starttec bloqué ETEINTE CLIGNOTE (cycle de 1 s) Défaut actif, contrôle en C0161 Messages défauts sur le clavier ou dans le programme de paramétrage Global Drive Control Conseil ! Avec le réglage de C0171 = 0.0 s, le message défaut TRIP doit être acquitté...
  • Page 163 Show/Hide Bookmarks Détection et élimination des défauts Messages défauts Affichage Défaut Origine Remède Clavier de cde Surveillance PTC Moteur trop chaud en raison des Vérifier le dimensionnement de O O O O H H H H 3 3 3 3 (TRIP) courants trop élevés et des l’entraînement.

This manual is also suitable for:

Starttec e71mm402 a v 02 series