Use the and buttons to scroll to the desred parameter number . In the example below,
Parameter 19 s beng dsplayed, whch s the ACCELERATION TIME of the drve:
Use and to scroll to the desred
parameter number (the example s
Parameter 19 - ACCELERATION
TIME)
Once the desred parameter number s found, press the Mode button to dsplay the present
parameter settng . The upper rght-hand decmal pont wll begn blnkng, ndcatng that
the present parameter settng s beng dsplayed, and that t can be changed by usng
the and buttons .
Press Mode to dsplay present
parameter settng (example set-
tng s 20 .0)
Upper rght decmal pont blnks
Use and to change settng
(example settng changed to
30 .0)
Press Mode to store new settng
Pressng Mode wll store the new settng and also ext the PROGRAM mode . To change
another parameter, press the Mode key agan to re-enter the PROGRAM mode (the
parameter menu wll be accessed at the parameter that was last vewed or changed before
extng) . If the Mode key s pressed wthn two mnutes of extng the PROGRAM mode,
the password s not requred access the parameters . After two mnutes, the password
must be entered n order to access the parameters agan .
13.1
Setting Values in Tenths of Units Above 100
Parameter settngs and the keypad speed command can always be adjusted n tenths of
unt ncrements from 0 .0 to 99 .9 . Above 100 however, values can be set n whole unts or
tenths of unts, dependng on the settng of Parameter 16 - UNITS EDITING .
If Parameter 16 - UNITS EDITING s set to WHOLE UNITS (02), parameter values and
the keypad speed command can only be adjusted by whole unt ncrements above 100 .
For example, Parameter 19 - ACCELERATION TIME could not be set to 243 .7 seconds .
It could only be set to 243 or 244 seconds . Lkewse, the keypad speed command (set
usng the and buttons) could not be set to 113 .4 Hz . It could only be set to 113 or
114 Hz .
25