2.9
Mode group, channel, program operation, reset response (K1)
2.9.1
Signals to mode group (DB11)
DB11, ...
DBX0.0
AUTOMATIC mode
Edge evaluation: no
Signal state 1 or
AUTOMATIK mode is selected by the PLC program.
edge change
0 → 1
Signal state 0 or
AUTOMATIK mode is not selected by the PLC program.
edge change
1 → 0
Signal irrelevant for
DB11, ... DBX0.4 (operating mode, changeover inhibit) = 1
...
Corresponding to ....
DB11, ... DBX6.0 (active AUTOMATIC mode)
DB11, ...
DBX0.1
MDA mode
Edge evaluation: no
Signal state 1 or
MDA mode is selected by the PLC program.
edge change
0 → 1
Signal state 0 or
MDA mode is not selected by the PLC program.
edge change
1 → 0
Signal irrelevant for
DB11, ... D0.4 (operating mode, changeover inhibit) = 1
...
Corresponding to ....
DB11, ... DBX6.1 (active MDA mode)
DB11, ...
DBX0.2
JOG mode
Edge evaluation: no
Signal state 1 or
JOG mode is selected by the PLC program.
edge change
0 → 1
Signal state 0 or
JOG mode is not selected by the PLC program.
edge change
1 → 0
Signal irrelevant for
DB11, ... DBX0.4 (operating mode, changeover inhibit) = 1
...
Corresponding to ....
DB11, ... DBX6.2 (active JOG mode)
Basic logic functions: NC/PLC interface signals (Z1)
Function Manual, 11/2006, 6FC5397-0BP10-2BA0
2.9 Mode group, channel, program operation, reset response (K1)
Signal(s) updated: cyclic
Signal(s) updated: cyclic
Signal(s) updated: cyclic
Detailed Description