3. Remove the cartridge from the enclosure and place it in a safe location. Be sure
to remove all ejected cartridges from the enclosure when you complete Manual
mode operations.
4. Confirm that the eject operation is complete by performing the following steps:
a. On the Library Manager Action List, highlight the action item you want to
confirm.
To highlight an item, use the up arrow (↑) or down arrow (↓) key to move
the highlight bar to the desired action item.
b. To confirm the highlighted action item, press the Enter key.
Note: Be sure to confirm each ejected cartridge after completing the eject task.
Eject actions remain on the Action List until you confirm them manually.
5. Press the Refresh key (F9) to update the list.

Reviewing Unknown Volume Locations

Use this procedure if you are not sure where a volume should go. Youcan display
the volser From location and To location of the last 20 completed actions. Perform
the following steps and use this information to verify the accuracy of a completed
action item:
1. Press the Review key (F6) on the Library Manager Action List (Figure 242 on
page 387).
2. Press F12 to return to the Action List.
If the Manual Mode Review List (Figure 244) did not list the volume, use the
Locate Cartridge Home window (Figure 246 on page 395) to find a storage cell to
put the volume in.
Action
Mount
Eject
Mount
Mount
F1=Help F3=HideScreen F12=Cancel
Figure 244. Manual Mode Review List Window
Note: The operator pressing F4 on the Action List caused the ERROR indication.
You can only view this list. You perform the tasks (actions) from the Action List.
Review List
VOLSER
From
GKT333
Rack
2 B 40
SRJ485
Rack
1 A 7
EPF371
Device 200
SDR495
Rack
7 A 6
To
Device 200
Confirmed
Confirmed
Device 3E1
Confirmed
Device 201
ERROR (see Note)