B16 Vts Controls; B18, B10, And B20 Vts Operator Panel; B18, B10, And B20 Vts - Operator Panel; B18, B10, B20 Vts Controls - IBM TotalStorage 3494 Tape Library Operator's Manual

Table of Contents

Advertisement

3494 B16 VTS Controls

All control functions for the 3494 B16 VTS are integrated into the Library Manager
(see Chapter 6, "Advanced Operating Procedures," on page 125).

3494 B18, B10, and B20 VTS Operator Panel

The rear door of the 3494 B18, B10, and B20 VTSs holds the operator panel.
Figure 36 shows the location of the power control on the operator panel of the 3494
B18, B10, and B20 VTSs.
Figure 36. 3494 B18, B10, and B20 VTS - Operator Panel

3494 B18, B10, B20 VTS Controls

All control functions for the 3494 B18, B10, and B20 VTSs, other than emergency
power control, are integrated into the Library Manager. For more information, see
Chapter 6, "Advanced Operating Procedures," on page 125. See "3494 B18, B10,
and B20 VTS Operator Panel" for the Unit Emergency switch function.
52
3494 Tape Library Operator Guide
1 Unit Emergency switch
Setting the Unit Emergency switch to the O (OFF) position powers off the
3494 B18, B10, and B20 VTS immediately. Use this switch only in an
emergency. Do not use it to power on or power off the 3494 B18, B10, and
B20 VTS. Sudden removal of power in case of emergency may cause the
loss of data. The Unit Emergency switch must be in the | (ON) position to
allow remote control of the Model 3494 B18, B10, and B20 VTS power by
the associated 3494 Tape Library.
Note: Setting the Unit Emergency switch for the 3494 B18, B10, and B20
VTS to the O (OFF) position does not remove power from the
associated 3494 Tape Library.