Summary of Contents for IBM Accesser F5100

  • Page 1 IBM Cloud Object Storage System Version 3.14.12 Accesser F5100 Appliance Manual 3401-A02/3403-A02...
  • Page 2 • The information in Safety and environmental notices • The information in the IBM Environmental Notices and User Guide (provided on a DVD) This edition applies to IBM Cloud Object Storage System Accesser F5100 and is valid until replaced by new editions. ©...
  • Page 3: Table Of Contents

    Contents Figures......................... iv Tables........................v Safety and environmental notices................. vi Safety notices.............................. vi Environmental notices..........................ix Declared noise emissions........................ix Support information..................... xi Chapter 1. Appliance safety precautions..............1 Physical................................ 1 Electrical...............................1 Electronic components..........................1 Chapter 2. Specifications and requirements............3 Appliance specifications..........................
  • Page 4: Figures

    Figures 1. Rear of the appliance with the card slot highlighted..................3 2. Identifying the sections of the rack rails...................... 6 3. Remove the inner rails from both rail kits.....................7 4. Retracting the outer rail..........................7 5. Attaching the sections of the rack inner rails....................8 6.
  • Page 5 Tables 1. Declared noise emissions in accordance with ISO 9296(1,2,3)..............ix 2. Cabling requirements for the appliance....................... 3 3. Appliance location considerations........................4 4. Legend for front panel buttons and LEDs....................11 5. Legend for rear panel I/O Ports for the appliance..................13 6.
  • Page 6: Safety And Environmental Notices

    Suitability for telecommunication environment - This product is not intended to connect directly or indirectly by any means whatsoever to interfaces of public telecommunications networks. Examples of a caution and a danger notice. Numbers in parentheses refer to message numbers in the IBM Safety Notices publication G229-9054, which is included with your product.
  • Page 7 Safety and environmental notices vii...
  • Page 8 IBM Cloud Object Storage System: Accesser F5100 Appliance Manual...
  • Page 9: Environmental Notices

    Environmental notices This information contains all of the environmental notices for IBM Systems products in English and other languages. The IBM Systems Environmental Notices information includes statements on limitations, product information, product recycling and disposal, battery information, flat panel display, refrigeration and water-cooling systems, external power supplies, and safety data sheets.
  • Page 10 Directives) may govern noise level exposure in the workplace and may apply to you and your server installation. This IBM system is available with an optional acoustical door feature that can help reduce the noise emitted from this system. The actual sound pressure levels in your installation depend upon a variety of factors, including the number of racks in the installation;...
  • Page 11: Support Information

    Support information Technical support contacts. For more information on the product or help with troubleshooting, contact IBM Support at ibm.com/ mysupport or visit the Directory of worldwide contacts. © Copyright IBM Corp. 2016, 2020...
  • Page 12 IBM Cloud Object Storage System: Accesser F5100 Appliance Manual...
  • Page 13: Chapter 1. Appliance Safety Precautions

    ESD: • Use a grounded wrist strap that is designed to prevent ESDs. • Keep all components in their antistatic containers until ready for installation. © Copyright IBM Corp. 2016, 2020...
  • Page 14 • Remove any jewelry or metal objects from your body. They are excellent metal conductors that can create short circuits and harm you if they come into contact with printed circuit boards or areas where power is present. 2 IBM Cloud Object Storage System: Accesser F5100 Appliance Manual...
  • Page 15: Chapter 2. Specifications And Requirements

    Direct Attach Copper Any SFP+ passive or active direct attach copper cable compliant with the Cables SFF-8431 v4.1 and SFF-8472 v10.4 specifications is supported. For more information, see Intel documentation on Modules and Cables. © Copyright IBM Corp. 2016, 2020...
  • Page 16: Chapter 3. Install The Appliance Into A Rack

    Note: The maximum current draw is printed on a label on the appliance power supplies. The system might draw more than 15 Amps at startup (inrush current). 4 IBM Cloud Object Storage System: Accesser F5100 Appliance Manual...
  • Page 17 Table 3. Appliance location considerations (continued) Factor Comments Reliable ground A reliable ground must be maintained always. The rack itself must be grounded. Give particular attention to the power supply connections other than the direct connections to the branch circuit, such as the use of power strips.
  • Page 18: Appliance Installation

    Figure 2. Identifying the sections of the rack rails Release the inner rail Remove the inner rail from each rail kit, as shown in the following figure. 6 IBM Cloud Object Storage System: Accesser F5100 Appliance Manual...
  • Page 19 Figure 3. Remove the inner rails from both rail kits 1. Pull on the front release tab to unlock the inner rail from the rail kit. 2. Remove and set aside each inner rail. Retract the outer rail After releasing and removing the inner rail, retract the outer rail to its shortest length, as shown in the following figure.
  • Page 20 Figure 7. Push outer rail into rack post 6. Attach the back of the left outer rail to the rear rack post through a similar process, as shown in the following figure. 8 IBM Cloud Object Storage System: Accesser F5100 Appliance Manual...
  • Page 21 Figure 8. Attach back of outer rail 7. Repeat these steps for the right outer rail. The final assembly of both outer rails is shown in the following figure. Figure 9. Final outer rail assembly and mounting Lock the rail tabs Both chassis rails have a locking tab, which locks the appliance in place when: •...
  • Page 22 4. To ensure that the power is on, verify that the power and network link lights are lit and listen for running fans, as shown in the following figure. Figure 12. Front of appliance 10 IBM Cloud Object Storage System: Accesser F5100 Appliance Manual...
  • Page 23: Chapter 4. Appliance Physical Interface

    Individual disk activity LED (green) Individual disk status LED (blue/amber) Disk drive 0 Disk drive 1 Disk drive 2 Disk drive 3 Disk drive 4 Disk drive 5 Disk drive 6 Disk drive 7 © Copyright IBM Corp. 2016, 2020...
  • Page 24: Rear Panel

    The I/O ports are color coded per the PC 99 specification. The locations of the various I/O ports are shown in the following figure. Figure 14. Rear panel I/O ports for the appliance 12 IBM Cloud Object Storage System: Accesser F5100 Appliance Manual...
  • Page 25: Network Interface Ports

    Table 5. Legend for rear panel I/O Ports for the appliance Number Description Unused PCIe card slot (on riser card) 10 GbE NIC card Power supply 1 Power supply 2 UID button/LED 1 GbE RJ45 ports (2) 10/100 Mbit/s management port DB-15 video connector USB 2.0 ports (2) Network interface ports...
  • Page 26 70°C and restarts when the PSU temperature drops below 60°C. Hard drive carrier Each drive carrier has one LED with two states. Table 8. Conditions indicated by drive carrier LEDs Condition LED color Drive activity Green Drive failure 14 IBM Cloud Object Storage System: Accesser F5100 Appliance Manual...
  • Page 27: Chapter 5. Field Replaceable Units

    Chapter 5. Field replaceable units A number of components can be replaced in the field. Replacement parts Contact IBM Support for replacement parts for the appliance. The following customer serviceable replacement parts are available: • 4×8 GB Memory Modules • Power Supply Module •...
  • Page 28: Replace External Rear Components

    4. Push the new PSU into the power bay until you hear a click. Install an SFP+ / QSFP optical module 1. Log in to the device as localadmin. 2. At the command prompt, type poweroff. 16 IBM Cloud Object Storage System: Accesser F5100 Appliance Manual...
  • Page 29: Battery Removal And Installation

    CAUTION: Handle used batteries carefully. Do not damage the battery in any way; a damaged battery can release hazardous materials into the environment. Do not discard a used battery in the garbage or a public landfill. Refer to the IBM Systems Environmental Notices for battery disposal guidelines.
  • Page 30: Notices

    Consult your local IBM representative for information on the products and services currently available in your area. Any reference to an IBM product, program, or service is not intended to state or imply that only that IBM product, program, or service may be used. Any functionally equivalent product, program, or service that does not infringe any IBM intellectual property right may be used instead.
  • Page 31: Trademarks

    International Business Machines Corp., registered in many jurisdictions worldwide. Other product and service names might be trademarks of IBM or other companies. A current list of IBM trademarks is available on the web at Copyright and trademark information at www.ibm.com/legal/copytrade.shtml.
  • Page 32: Homologation Statement

    This product may not be certified in your country for connection by any means whatsoever to interfaces of public telecommunications networks. Further certification may be required by law prior to making any such connection. Contact an IBM representative or reseller for any questions. 20 IBM Cloud Object Storage System: Accesser F5100 Appliance Manual...
  • Page 34 IBM®...

This manual is also suitable for:

3401-a023403-a02

Table of Contents