IBM TotalStorage 3494 Tape Library Operator's Manual page 477

Table of Contents

Advertisement

Table 25. DFSMS Messages Based on Library Failure or Exception Conditions (continued)
Resulting Console Message
CBR3779I Damaged volume volser ejected from library
library-name.
Damaged volume volser has been ejected from library
library-name. The cartridge has been damaged physically,
such that it cannot be loaded on a tape device. Either the
leader block is missing, or the tape medium has become
detached from the leader block.
CBR3781I No {MEDIA1|MEDIA2|MEDIA3|MEDIA4|
MEDIA5|MEDIA6|MEDIA7|MEDIA8} scratch
volumes available in library library-name.
A library operation requires a scratch volume of the
indicated media type, and there are none available in the
3494 Tape Library.
CBR3782I Volume volser in library library-name
external label missing or unreadable.
The external cartridge label for volume volser in library
library-name is missing, or the library vision system
cannot read it correctly. The 3494 Tape Library cannot
perform volume verification. Mount, demount, and eject
requests are completed without verification.
CBR3783E Library Manager switchover in library
library-name in progress.
When the 3494 HA1 Option is installed, this indicates
that the standby Library Manager is in the process of
switching over to active. The switchover may be the
result of a Library Manager-detected unrecoverable error
or an operator request initiated through the Library
Manager.
CBR3784I The Library Manager switchover in library
library-name is now complete.
When the 3494 HA1 Option is installed, this indicates
that a failure on the active Library Manager has resulted
in a switchover to the standby Library Manager. This
message indicates that the switchover is complete.
CBR3785E Copy operations disabled in library
library-name.
Copying of data between the VTSs in PtP VTS
library-name can no longer be performed. Possible causes
are:
v One of the VTSs has become unavailable.
v All ESCON or FICON links to one of the VTSs have
become unavailable.
CBR3786E VTS operations degraded in library
library-name.
PtP VTS library-name does not have all of its elements
available, either because of failure or service
representative action.
Action
1. Remove the cartridge from the output station and
repair or replace it.
2. Clear the item from the Intervention Required
window. See "Intervention Conditions" on page 459
for details.
Either add volumes of the appropriate media type to the
3494 Tape Library or perform a scratch cycle though
your tape management system to convert volumes to
scratch in the 3494 Tape Library.
1. Issue a 3494 Tape Library request to eject the volume
from the 3494 Tape Library and apply a new
cartridge external label, if it has not already been
ejected.
2. Place the cartridge in the convenience input station.
3. Clear the item from the Intervention Required
window. See "Intervention Conditions" on page 459
for details.
See "Library Manager Failure in DFSMS/MVS (z/OS)"
on page 435 for recovery procedures. CBR3784I indicates
when the switchover is complete.
Any outstanding mount requests (CBR4196D) can be
responded to and any new requests to the 3494 Tape
Library can be submitted. See "Start Library Manager
and Host Recovery Procedure (DFSMS/MVS or z/OS)"
on page 437 to recover from inserts or ejects that may
have been in progress at the time of the failure.
Call your service representative.
Unless your service representative has notified you that
the PtP VTS will become degraded, call your service
representative.
Chapter 8. Problem Determination Procedures
451

Advertisement

Table of Contents
loading

Table of Contents