Universal Robots UR10 Service Manual page 76

With cb3.0/3.1-controller
Hide thumbs Also See for UR10:
Table of Contents

Advertisement

C50A5
Powersupply voltage too low
C50A6
Powersupply voltage too high
C50A11
Voltage not detected at 24V
rail after startup
C50A15
Warning, waiting for
SafetySYS2
C50A16
The Teach Pendant does not
respond
C50A17
The Euromap67 interface does
not respond
C50A18
Warning, waiting for
SafetySYS1
C50A20
5V, 3V3 or ADC error (5V too
high)
C50A21
5V, 3V3 or ADC error (5V too
low)
C50A22
Robot current sensor reading
too high
C50A23
Robot current sensor reading
too low
C50A24
48V not present (Check
internal connection)
This error can have several root causes and you have to measure the voltage some places.
There are 3 different components that could be the root cause and you have to measure the
voltage to determine which one of them that is the faulty one.
- 48 V power supply
- Current distributor
- Safety Control Board.
Find the schematic drawing in this service manual
C50A25
Robot voltage present at 48V
PSU powereup
C50A26
Voltage present on unpowered
48V power supply
C50A27
12V, 3V3 or ADC error (12V
too high)
C50A28
12V, 3V3 or ADC error (12V
too low)
C50A29
Analog I/O error (-12V too
high)
C50A30
Analog I/O error (-12V too
low)
C50A31
The other safetySYS do not
initialize
C50A40
Wrong voltage from PSU1
C50A41
Wrong voltage from PSU2
C50A42
Voltage will not disappear
from PSU
All rights reserved
24 V to the I/O interface in the
controller
SafetySYS2 = Processor B on
Safety Control Board
Loose wire or incorrect safety
configuration. Message comes
from Safety Control Board
Loose wire or incorrect safety
configuration
SafetySYS1 = Processor A on
Safety Control Board
76
Check the cable or change
in the Safety Configuration
of the Installation the
miscellaneous settings
Check the cable or change
in the Safety Configuration
of the Installation the
miscellaneous settings
Servicemanual_UR10_en_3.1.3