B.2 b: Application
Application parameters configure the source of the Run command, DC Injection Braking, Speed Search, timer functions, PID
control, the Dwell function, Energy Savings, and a variety of other application-related settings.

b1: Operation Mode Selection

u
No.
(Addr.
Name
Hex)
b1-01
Frequency Reference
(180)
Selection 1
b1-02
Run Command
(181)
Selection 1
b1-03
Stopping Method Selection
(182)
b1-04
Reverse Operation Selection
(183)
b1-07
LOCAL/REMOTE Run
(186)
Selection
b1-08
Run Command Selection in
(187)
Programming Mode
b1-11
Run Delay Time Setting
(1DF)
b1-14
Phase Order Selection
(1C3)
b1-15
Frequency Reference
(1C4)
Selection 2
b1-16
Run Command
(1C5)
Selection 2
b1-17
Run Command at Power Up
(1C6)
u

b2: DC Injection Braking and Short Circuit Braking

No.
(Addr.
Name
Hex)
b2-01
DC Injection Braking Start
(189)
Frequency
b2-02
DC Injection Braking
(18A)
Current
b2-03
DC Injection Braking Time
(18B)
at Start
YASKAWA ELECTRIC TOEP YAIP1U 01B YASKAWA AC Drive - P1000 Quick Start Guide
0: Digital operator
1: Analog input terminals
2: MEMOBUS/Modbus communications
3: Option PCB
4: Pulse input (terminal RP)
0: Digital operator
1: Digital input terminals
2: MEMOBUS/Modbus communications
3: Option PCB
0: Ramp to stop
1: Coast to stop
2: DC Injection Braking to stop
3: Coast with timer
0: Reverse enabled.
1: Reverse disabled.
0: An external Run command must be cycled at the new source in order to be
activated.
1: An external Run command at the new source is accepted immediately.
0: Run command is not accepted while in Programming Mode.
1: Run command is accepted while in Programming Mode.
2: Prohibit entering Programming Mode during run.
After a Run command is entered, the drive output waits until this delay time
has passed before starting.
0: Standard
1: Switch phase order (reverses the direction of the motor)
Enabled when an input terminal set for "External reference" (H1-oo = 2)
closes.
0: Digital operator
1: Terminals (analog input terminals)
2: MEMOBUS/Modbus communications
3: Option card
4: Pulse train input
Enabled when a terminal set for "External reference" (H1-oo = 2) closes.
0: Digital operator
1: Digital input terminals
2: MEMOBUS/Modbus communications
3: Option card
0: Disregarded. A new Run command must be issued after power up.
1: Allowed. Motor will start immediately after power up if a Run command
is already enabled.
Sets the frequency at which DC Injection Braking starts when "Ramp to stop"
(b1-03 = 0) is selected.
Sets the DC Injection Braking current as a percentage of the drive rated current. Default: 50%
Sets DC Injection Braking time at start. Disabled when set to 0.00 seconds.
Description
Description
B.2 b: Application
Values
Page
Default: 1
92
Range: 0 to 4
Default: 1
93
Range: 0 to 3
Default: 0
94
Range: 0 to 3
Default: 0
Range: 0, 1
Default: 0
Range: 0, 1
Default: 0
Range: 0 to 2
Default: 0 s
Min.: 0
Max.: 600
Default: 0
Range: 0, 1
Default: 0
Range: 0 to 4
Default: 0
Range: 0 to 3
Default: 0
Range: 0, 1
Values
Page
Default: 0.5 Hz
Min.: 0.0
96
Max.: 10.0
Min.: 0
Max.: 100
Default: 0.00 s
Min.: 0.00
Max.: 10.00
185
B