3.7 Control Circuit Wiring

3.7

Control Circuit Wiring

Control Circuit Terminal Block Functions

u
Drive parameters determine which functions apply to the multi-function digital inputs (S1 to S8), multi-function digital outputs
(M1 to M4), multi-function analog inputs (A1 to A3), and multi-function analog monitor output (FM, AM). The default setting
is listed next to each terminal in
Sudden Movement Hazard. Always check the operation and wiring of control circuits after being wired. Operating a drive with
WARNING!
untested control circuits could result in death or serious injury.
Sudden Movement Hazard. Confirm the drive I/O signals and external sequence before starting test run. Setting parameter
WARNING!
A1-03 may change the I/O terminal function automatically from the factory setting.
comply may result in death or serious injury.
Input Terminals
n
Table 3.7
lists the input terminals on the drive. Text in parenthesis indicates the default setting for each multi-function input.
Type
No.
Multi-function input 1
S1
(Closed: Forward run, Open: Stop)
Multi-function input 2
S2
(Closed: Reverse run, Open: Stop)
Multi-function input 3
S3
(External fault, N.O.)
Multi-function input 4
S4
(Fault reset)
Multi-function input 5
S5
(Multi-step speed reference 1)
Multi-Function
Multi-function input 6
S6
Digital Inputs
(Multi-step speed reference 2)
Multi-function input 7
S7
(Jog reference)
Multi-function input 8
S8
(Baseblock command (N.O.))
SC
Multi-function input common
SP
Digital input power supply +24 Vdc
Digital input power supply 0 V
SN
24 V transducer power supply 0 V
Multi-function pulse train input
RP
(Frequency reference)
+V
Power supply for analog inputs
+24 Vdc transducer power supply for customer
24 V
use
Multi-function analog input 1
Analog Inputs /
A1
(Frequency reference bias)
Pulse Train
Input
Multi-function analog input 2
A2
(Frequency reference bias)
Multi-function analog input 3
A3
(Frequency reference bias)
AC
Frequency reference common
E (G) Ground for shielded lines and option cards
66
Figure 3.1
on page 43.
Table 3.7 Control Circuit Input Terminals
Terminal Name (Function)
Refer to Application Selection on page
Function (Signal Level) Default Setting
• Photocoupler
• 24 Vdc, 8 mA
Refer to Sinking/Sourcing Mode for Digital Inputs on page
71.
Multi-function input common
24 Vdc power supply for digital inputs, 150 mA max
NOTICE:
Do not jumper or short terminals SP and SN. Failure
to comply will damage the drive.
• Input frequency range: 0 to 32 kHz
• Signal Duty Cycle: 30 to 70%
• High level: 3.5 to 13.2 Vdc, low level: 0.0 to 0.8 Vdc
• Input impedance: 3 kΩ
10.5 Vdc (max allowable current 20 mA)
150 mA maximum capacity
• -10 to 10 Vdc, 0 to 10 Vdc (input impedance: 20 kΩ)
• 4 to 20 mA, 0 to 20 mA (input impedance: 250 Ω)
• Voltage or current input must be selected by jumper S1 and H3-01.
• -10 to 10 Vdc, 0 to 10 Vdc (input impedance: 20 kΩ)
• 4 to 20 mA, 0 to 20 mA (input impedance: 250 Ω)
• Voltage or current input must be selected by jumper S1 and H3-09.
• -10 to 10 Vdc, 0 to 10 Vdc (input impedance: 20 kΩ)
• 4 to 20 mA, 0 to 20 mA (input impedance: 250 Ω)
• Voltage or current input must be selected by jumper S1 and H3-05.