YASKAWA P1000 Quick Start Manual page 109

Hide thumbs Also See for P1000:
Table of Contents

Advertisement

Setting
0
During Run
1
Zero Speed
2
Speed Agree 1
3
User-Set Speed Agree 1
4
Frequency Detection 1
5
Frequency Detection 2
6
Drive Ready
7
DC Bus Undervoltage
8
During Baseblock (N.O.)
9
Frequency Reference Source
A
Run Command Source
B
Torque Detection 1 (N.O.)
C
Frequency Reference Loss
D
Braking Resistor Fault
E
Fault
F
Through Mode
10
Minor Fault
11
Fault Reset Command Active
12
Timer Output
13
Speed Agree 2
14
User-Set Speed Agree 2
15
Frequency Detection 3
16
Frequency Detection 4
17
Torque Detection 1 (N.C.)
18
Torque Detection 2 (N.O.)
19
Torque Detection 2 (N.C.)
1A
During Reverse
1B
During Baseblock (N.C.)
<2> Not available in models 2A0169 to 2A0415 and 4A0088 to 4A1200.
Setting 2: Speed Agree 1 (f
Closes when the actual output frequency is within the Speed Agree Width (L4-02) of the current frequency reference regardless
of the direction.
Status
Open
Output frequency or motor speed does not match the frequency reference while the drive is running.
Closed
Output frequency or motor speed is within the range of frequency reference ±L4-02.
Note:
Detection works in forward and reverse.
Speed agree 1
YASKAWA ELECTRIC TOEP YAIP1U 01B YASKAWA AC Drive - P1000 Quick Start Guide
Table 4.28 Multi-Function Digital Output Terminal Settings
Function
/f
Agree 1)
ref
out
Frequency
reference
Output Frequency
or Motor Speed
OFF
ON
Figure 4.21 Speed Agree 1 Time Chart
Setting
1E
Restart Enabled
1F
Motor Overload Alarm (oL1)
109
20
Drive Overheat Pre-Alarm (oH)
110
22
Mechanical Weakening Detection
2F
Maintenance Period
37
During Frequency Output
38
Drive Enabled
39
Watt Hour Pulse Output
3C
LOCAL/REMOTE Status
3D
During Speed Search
3E
PID Feedback Low
3F
PID Feedback High
4A
During KEB Operation
4C
During Fast Stop
4D
oH Pre-Alarm Time Limit
<2>
Braking Transistor Fault (rr)
4E
<2>
Braking Resistor Overheat (rH)
4F
50
Waiting to Run
51
Sequence timer 1
52
Sequence timer 2
53
Sequence timer 3
54
Sequence timer 4
58
UL6 Detected
60
Internal Cooling Fan Alarm
71
Secondary PI Feedback Low
72
Secondary PI Feedback High
100 to 192 Functions 0 to 92 with Inverse Output
Description
L4-02
4.6 Basic Drive Setup Adjustments
Function
L4-02
4
109