B.5 E: Motor Parameters
No.
(Addr.
Name
Hex)
F6-64 to
F6-71
Reserved
(3DF to
3C8)
F7-01
(3E5)
IP Address 1
<2>
F7-02
(3E6)
IP Address 2
<2>
F7-03
(3E7)
IP Address 3
<2>
F7-04
(3E8)
IP Address 4
<2>
F7-05
Subnet Mask 1
(3E9)
F7-06
Subnet Mask 2
(3EA)
F7-07
Subnet Mask 3
(3EB)
F7-08
Subnet Mask 4
(3EC)
F7-09
Gateway Address 1
(3ED)
F7-10
Gateway Address 2
(3EE)
F7-11
Gateway Address 3
(3EF)
F7-12
Gateway Address 4
(3E0)
F7-13
Address Mode at Startup
(3F1)
F7-14
Duplex Mode Selection
(3F2)
F7-15
Communication Speed
(3F3)
Selection
F7-16
Communication Loss
(3F4)
Timeout
F7-17
EtherNet/IP Speed Scaling
(3F5)
Factor
F7-18
EtherNet/IP Current Scaling
(3F6)
Factor
F7-19
EtherNet/IP Torque Scaling
(3F7)
Factor
F7-20
EtherNet/IP Power Scaling
(3F8)
Factor
F7-21
EtherNet/IP Voltage Scaling
(3F9)
Factor
200
Reserved for Dynamic I/O Assembly Parameters.
Sets the most significant octet of network static IP address.
Sets the second most significant octet of network static IP address.
Sets the third most significant octet of network static IP address.
Sets the fourth most significant octet of network static IP address.
Sets the most significant octet of network static Subnet Mask.
Sets the second most significant octet of network static Subnet Mask.
Sets the third most significant octet of network static Subnet Mask.
Sets the fourth most significant octet of network static Subnet Mask.
Sets the most significant octet of network Gateway address.
Sets the second most significant octet of network Gateway address.
Sets the third most significant octet of network Gateway address.
Sets the fourth most significant octet of network Gateway address.
Select the option address setting method
<3>
0: Static
1: BOOTP
2: DHCP
Selects duplex mode setting.
0: Half duplex forced
1: Auto-negotiate duplex mode and communication speed
2: Full duplex forced
Sets the communication speed
10: 10 Mbps
100: 100 Mbps
Sets the timeout value for communication loss detection in tenths of a second.
A value of 0 disables the connection timeout.
Example: An entered value of 100 represents 10.0 seconds.
Sets the scaling factor for the speed monitor in EtherNet/IP Class ID 2AH
Object.
Sets the scaling factor for the output current monitor in EtherNet/IP Class ID
2AH Object.
Sets the scaling factor for the torque monitor in EtherNet/IP Class ID 2AH
Object.
Sets the scaling factor for the power monitor in EtherNet/IP Class ID 2AH
Object.
Sets the scaling factor for the voltage monitor in EtherNet/IP Class ID 2AH
Object.
YASKAWA ELECTRIC TOEP YAIP1U 01B YASKAWA AC Drive - P1000 Quick Start Guide
Description
Values
Page
Default: 192
Range: 0 to 255
Default: 168
Range: 0 to 255
Default: 1
Range: 0 to 255
Default: 20
Range: 0 to 255
Default: 255
Range: 0 to 255
Default: 255
Range: 0 to 255
Default: 255
Range: 0 to 255
Default: 0
Range: 0 to 255
Default: 192
Range: 0 to 255
Default: 168
Range: 0 to 255
Default: 1
Range: 0 to 255
Default: 1
Range: 0 to 255
Default: 2
Range: 0 to 2
Default: 1
Range: 0 to 2
Default: 10
Range: 10, 100
Default: 0
Min.: 0
Max.: 300
Default: 0
Min.: -15
Max.: 15
Default: 0
Min.: -15
Max.: 15
Default: 0
Min.: -15
Max.: 15
Default: 0
Min.: -15
Max.: 15
Default: 0
Min.: -15
Max.: 15

Hide quick links: