YASKAWA P1000 Quick Start Manual page 188

Hide thumbs Also See for P1000:
Table of Contents

Advertisement

B.2 b: Application
No.
(Addr.
Name
Hex)
b5-14
PID Feedback Loss
(1B2)
Detection Time
b5-15
PID Sleep Function Start
(1B3)
Level
b5-16
PID Sleep Delay Time
(1B4)
b5-17
PID Accel/Decel Time
(1B5)
b5-18
PID Setpoint Selection
(1DC)
b5-19
(1DD)
PID Setpoint Value
<1>
b5-20
PID Setpoint Scaling
(1E2)
b5-34
(19F)
PID Output Lower Limit
b5-35
(1A0)
PID Input Limit
b5-36
PID Feedback High
(1A1)
Detection Level
b5-37
PID Feedback High
(1A2)
Detection Time
b5-38
PID Setpoint User Display
(1FE)
b5-39
PID Setpoint Display Digits
(1FF)
b5-40
Frequency Reference
(17F)
Monitor Content during PID
b5-41
PI Output 2 Unit Selection
(160)
188
Sets a delay time for PID feedback loss.
Sets the frequency level that triggers the sleep function.
Sets a delay time before the sleep function is triggered.
Sets the acceleration and deceleration time to PID setpoint.
0: Disabled
1: Enabled
Sets the PID target value as a percentage of the maximum output frequency
when b5-18 is set to 1.
Note:
Values set above b5-38 will be internally limited to b5-38
0: 0.01 Hz units
1: 0.01% units (100% = max output frequency)
2: RPM (number of motor poles must entered)
3: User-set (set scaling to b5-38 and b5-39, units based on b5-46 setting)
Sets the minimum output possible from the PID controller as a percentage of
the maximum output frequency.
Limits the PID control input (deviation signal) as a percentage of the maximum
output frequency. Acts as a bipolar limit.
Sets the PID feedback high detection level as a percentage of the maximum
output frequency.
Sets the PID feedback high level detection delay time.
Scales the PID units to the maximum output frequency.
0: No decimal places
1: One decimal place
2: Two decimal places
3: Three decimal places
0: Display the frequency reference (U1-01) after PID compensation has been
added.
1: Display the frequency reference (U1-01) before PID compensation has been
added.
0: WC (Inch of water)
1: PSI (Pounds per square inch)
2: GPM (Gallons per minute)
3: F (Degrees Fahrenheit)
4: CFM (Cubic feet per minute)
5: CMH (Cubic meters per hour)
6: LPH (Liters per hour)
7: LPS (Liters per second)
8: Bar (Bar)
9: Pa (Pascal)
10: C (Degrees Celsius)
11: Mtr (Meters)
12: Ft (Feet)
13: LPM (Liters per minute)
14: CMM (Cubic meters per minute)
15: "Hg (Inches of Mercury)
25: None
YASKAWA ELECTRIC TOEP YAIP1U 01B YASKAWA AC Drive - P1000 Quick Start Guide
Description
Values
Page
Default: 1.0 s
Min.: 0.0
Max.: 25.5
Default: 0.0 Hz
Min.: 0.0
Max.: 400.0
Default: 0.0 s
Min.: 0.0
Max.: 25.5
Default: 0.0 s
Min.: 0.0
Max.: 6000.0
Default: 0
Range: 0, 1
Default: 0.00%
Min.: 0.00
Max.: 600.00
Default: 1
Range: 0 to 3
Default: 0.00%
Min.: -100.00
Max.: 100.00
Default: 1000.0%
Min.: 0.0
Max.: 1000.0
Default: 100%
Min.: 0
Max.: 100
Default: 1.0 s
Min.: 0.0
Max.: 25.5
Default: 10000
Min.: 1
Max.: 60000
Default: 2
Range: 0 to 3
Default: 0
Range: 0, 1
Default: 0
Range: 0 to 15; 25