Drive fails to operate properly due to noise
interference
Overexcitation gain is set too high
Run command was applied while motor was
coasting
The rated output current of the drive is too
small
Digital Operator Display
oFA03 to oFA06
to
oFA10, oFA11
,
to
oFA12 to oFA17
oFA30 to oFA43
to
oFb03 to oFb11
to
oFb12 to oFb17
to
to
oFC03 to oFC11
to
oFC12 to oFC17
oFC50 to oFC55
to
Cause
Surrounding temperature is too high
YASKAWA ELECTRIC TOEP YAIP1U 01B YASKAWA AC Drive - P1000 Quick Start Guide
• Review the possible solutions provided for handling noise interference.
• Review the section on handling noise interference and check the control circuit lines, main circuit lines,
and ground wiring.
• Check if the fault occurs simultaneously with overexcitation function operation.
• Consider motor flux saturation and reduce the value of n3-13 (Overexcitation Deceleration Gain).
• Set b3-01 to 1 to enable Speed Search at Start.
• Program the Speed Search command input through one of the multi-function contact input terminals
(H1-oo = 61 or 62).
Use a larger drive.
Option Card Connection Error at Option Port CN5-A
oFA00
Option compatibility error
Option Card Fault at Option Port CN5-A
oFA01
Option not properly connected
Option Card Error Occurred at Option Port CN5-A
Option Card Connection Error (CN5-A)
Communication Option Card Connection Error (CN5-A)
Option Card Fault at Option Port CN5-B
oFb00
Option compatibility error
Option Card Fault at Option Port CN5-B
oFb01
Option not properly connected
Option Card Fault at Option Port CN5-B
oFb02
Same type of option card is currently connected
Option card error occurred at Option Port CN5-B
Option Card Connection Error at Option Port CN5-C
oFC00
Option compatibility error
Option Card Fault at Option Port CN5-C
oFC01
Option not properly connected
Option Card Fault at Option Port CN5-C
oFC02
Same type of option card is currently connected
Option Card Error Occurred at Option Port CN5-C
Option Card Error Occurred at Option Port CN5-C
Heatsink Overheat
oH
The heatsink temperature exceeded the overheat pre-alarm level set to L8-02. The default value for L8-02
is determined by drive capacity (o2-04).
• Check the temperature surrounding the drive. Verify temperature is within drive specifications.
• Improve the air circulation within the enclosure panel.
• Install a fan or air conditioner to cool the surrounding area.
• Remove anything near the drive that might be producing excessive heat.