3 Installation
3.3 Flush mounting in control panel
3.3.2.4 Size 1: Surface mounting with PKZ or PKE
1
72
DS7 Soft starter 09/16 MN03901001Z-EN www.eaton.com
2
Figure 55: Mounting of size 1 devices (up to 12 A)
The size 1 DS7 soft starter (up to 12 A) can be connected directly to a PKZ or
PKE motor-protective circuit-breaker. This electronic motor-starter
combination can be mounted directly on a mounting plate, a mounting rail or
on busbar adapter. Accessories required:
PKZM0-XDM12 wiring kit for connecting a DS7
soft starter directly to a PKZ or PKE motor-
protective circuit-breaker
optional, variant 1:
PKZM0-XC45L top-hat rail adapter
optional, variant 2:
BBA0L-25 busbar adapter
3
5
4
= ①
= ②
= ③