8.9.6.3 SmartWire-DT write request – Read job
Only individual parameter reading is supported (i.e., array and multiple
parameter reading is not supported). The parameter request's frame length
is set at 10 bytes.
Various objects can be transmitted in the parameter channel – these objects
are identified by what is referred to as a PNU (parameter number) and a
subindex. The write request includes a declaration that specifies that the job
is a read job.
Byte
Designation
0
Request Reference
1
Request ID
2
DO-ID
3
No. of Paramters
4
Attribute
5
No. of Elements
6, 7
Parameter number
8, 9
Subindex
In this case, the number of bytes is always 10.
DS7 Soft starter 09/16 MN03901001Z-EN www.eaton.com
Description
Request identification:
Unique identification for a request/response pair for the master.
The master can increment the identification number for each new
request in the application.
It will be echoed by the DS7-SWD soft starter after this.
01
- FF
(i.e. 1
- 255
)
hex
hex
dec
dec
Request ID:
The type of request is specified here.
01
: Read request
hex
Drive-Object-ID:
00
hex
Number of parameters:
Only individual parameter processing is supported.
01
hex
Attribute:
Defines which object type should be accessed.
10
(16
): Value
hex
dec
Number of elements:
Address of the parameter that should be accessed
PNU 0 - PNU 999: 00
(for subindex 0 only)
hex
PNU 0 - PNU 999 (without 202): 01
Parameter number (PNU):
Address of the parameter that should be accessed
0000
- FFFF
(i. e. 0
- 65535
hex
hex
dec
Subindex:
Address of the parameter's first field element or start of the text
0000
- FFFF
(i. e. 0
- 65535
hex
hex
dec
8 SmartWire-DT
8.9 Programming
hex
)
dec
)
dec
199