8.9.3.11 Profile 10: Outputs (control)
Output bytes 0 and 1 (Short) are mapped as follows on SmartWire-DT.
Table 37: Profile 10: Output bytes 0 and 1
Byte
Bit
Designation
0
0
EN_Set
(Control
DS7)
1
2
EN_Op
3
FaultAck
4 - 7
1
0 - 7
Byte 1 is only needed for internal SmartWire-DT-specific functions.
DS7 Soft starter 09/16 MN03901001Z-EN www.eaton.com
8 SmartWire-DT
8.9 Programming
Meaning
Enable Setpoint, DS7 Start/Stop:
EN_Set enables the setpoint value and starts or
stops the motor with the ramp function.
0: (deactivate setpoint value)
1: (activate setpoint value)
Not used
Operation released:
0: Stop (immediate disconnection of the output)
1: Operation
Fault Acknowledge
0: Do not acknowledge current fault
1: Acknowledge current fault (rising edge: 0 → 1)
Not used
Not used
179