3 Installation
3.3 Flush mounting in control panel
3.3.1.2 Device fan DS7-FAN-100 / DS7-FAN-200
66
DS7 Soft starter 09/16 MN03901001Z-EN www.eaton.com
The optional DS7-FAN-100 and DS7-FAN-200 fans are mounted on the back
of the DS7 soft starter. They are fastened onto the heat sink using four
screws.
Figure 44: Fitting the fan (basic principle)
Figure 45: Mounting the DS7-FAN100/DS7-FAN200
▶ Insert the nuts into the corresponding cutouts in the cooling fins [1].
▶ Place the DS7-FAN-100 / DS7-FAN-200 fan on top of the heat sink's
bottom [2].
▶ Secure the fan with the screws [3].
The maximum tightening torque is 2 Nm.
The required nuts and screws are included with the fan.