Operator action
While the PCU is ramping up (after switching the controller off and then on again)
1. Select the "Service menu" [hidden menu entry] in the Boot Manager.
2. Press key <E>: Restore Windows Partition E (Emergency)
3. Enter one of the passwords for authorization levels 0 - 3.
Result
The warning "The Windows Partition E: will be overwritten" is displayed and the restore
process for partition E: is started after another prompt. On completion of the partition E data
restore, the message "Restore finished" is displayed.
When Windows next boots, partition E: is checked by the CHKDSK (Check Disk) routine.
4.3

Backing up/restoring data with a TCU configuration

4.3
application
If a configuration contains one or more TCUs, data backup/restoration cannot be carried out
with service programs on the DOS level.
This is why the Service desktop provides a link to the "ServiceCenter" program. The
backup/restore functions are carried out here, as when they are called in DOS, e.g., creating
an image, restoring, marking as an emergency image, etc.
Overview
Double-clicking on "ServiceCenter" opens the selection box below:
PCU Basesoftware (IM6)
Commissioning Manual, 10/2006, 6FC5397-0DP10-0BA0
The main menu is displayed:
The system prompts you to enter a password:
– system
– Manufacturer
– Service
– Customer
4.3 Backing up/restoring data with a TCU configuration