1.2
User administration
1.2
1.2.1
Which users are set up?
Overview
The users are managed in the "ServiceCenter Users", so that the commissioner/service user
no longer has to make corresponding settings directly in the registry.
The preset users are:
● The "auduser".
● The "operator"
For the HMI user and service user, individual settings can be configured for boot up, the HMI
program and service.
Notice
In the PCU Basesoftware version 7.6, only one service user ("auduser" is the default) and
only one HMI user with the fixed name of "operator" are supported.
User
Each user is from one user type and belongs to one user group.
User type
A user can be assigned to the following user types:
User types
HMI Users
Service user
The user types are implemented under Windows in user groups with various user rights.
PCU Basesoftware (IM6)
Commissioning Manual, 10/2006, 6FC5397-0DP10-0BA0
The "auduser" is a service user type of user and belongs to the system administrators'
user group. The system administrators have the user rights of a local administrator.
The "operator" is an HMI user type of user and belongs to the operators' user group. The
operators have limited user rights.
Task card
Boot up of the PCU
•
Operating the HMI program
•
Service tasks
•
Boot up of the PCU
•
Operating the HMI program
•
Commissioning a system
1.2 User administration
1-5