Backing up and Restoring Data
4.1 Backing up/restoring data with an Ethernet connection
Operator actions
While the PCU is ramping up (after switching the controller off and then on again)
1. Select the "Service menu" [hidden menu entry] in the Boot Manager.
2. Press key <7>: Backup/Restore
3. Enter one of the passwords for authorization levels 0 - 2.
Your Choice [1, 4, 5, 9]?
4. Press key <1>:
Your Choice [1, 2, 3, 4, 9]?
Note
The path names are default settings and depend on the drive. You can change these path
names.
4-2
The main menu is displayed:
The system prompts you to enter a password:
The following menu is displayed:
PLEASE SELECT
1 Harddisk Backup/Restore with GHOST
4 Partitions Backup/Restore with GHOST (locally)
5 ADDM Backup/Restore
9 Back to Main Menu
The following menu is displayed:
PLEASE SELECT
1 Configure GHOST Parameters
2 Harddisk Backup to <Path>, Mode ...
3 Harddisk Restore from <Path>, Mode ...
4 Switch to other Version of GHOST
9 Back to previous Menu
Commissioning Manual, 10/2006, 6FC5397-0DP10-0BA0